background image

Important safety information    

en

11

(

Important safety 

information

Important safety information

Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.
The width of the extractor hood must 

correspond at least with the width of the hob.
For the installation, observe the currently valid 

building regulations and the regulations of the 

local electricity and gas suppliers.
When conveying the exhaust air, official and 

legal regulations (e.g. state building 

regulations) must be followed.

:

Warning – Risk of death! 

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

Summary of Contents for LB55565GB

Page 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH EVK JURXS FRP ZHOFRPH en Instructions for installation and use Extractor hood ...

Page 2: ...stallation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance...

Page 3: ...ase consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 mont...

Page 4: ...use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope 7Environmental protection EnvironmentalprotectionYour new appliance is particularly energy efficient Here y...

Page 5: ...pliance OperatingtheapplianceThese instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Note Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Control panel Setting the fan Switc...

Page 6: ...s Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with the cleaning agents Removing metal grease filter 1 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand Area Cleaning agent Stainless steel Hot soapy water Clean with a dish cloth and then dry with a soft cloth ...

Page 7: ...r Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may occur This has no effect on the function of the metal mesh grease filters Do not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in Installing the metal mesh grease filter...

Page 8: ...the activated charcoal filter using the enclosed sealing strips 5 Insert the activated charcoal filter at the rear fold it up and lock it in the centre using the wing nut If the appliance has a spacer rail reinsert this 6 Reinsert the metal grease filter Removing the activated charcoal filter 1 Remove the metal grease filter 2 If the appliance has a spacer rail remove this Unlock the activated cha...

Page 9: ... sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manuf...

Page 10: ...pply to your appliance This appliance is installed in chimneys or chimney hoods Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation If the extractor hood is used in exhaust air mode a one way flap must be installed Appliance width 53 cm Appliance width 73 cm...

Page 11: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 12: ...ording to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExha...

Page 13: ...stallation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the housing The extractor hood must be installed on the lower edge so that it is flush with the housing The housing must cover the entire cooking area The max weight of the ext...

Page 14: ...has a rectangular air outlet the air inlet provided must be screwed in tightly via the air outlet 5Installation InstallationFinal fitting stage 1 Remove the metal grease filter 2 Establish the electrical connection 3 Push the extractor hood in the housing up until the mounting spring at the front and rear clicks into place 4 Screw the extractor hood in tightly 5 Insert and lock the metal grease fi...

Page 15: ...oving the appliance 1 Disconnect the electrical connection 2 Undo the screws 3 Disconnect the pipes 4 Hold the extractor hood down Pull at the front and rear of the mounting spring 5 Pull the extractor hood downwards and out ...

Page 16: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 6 DXVJHUlWH PE DUO HU 6WU 0 QFKHQ VLHPHQV KRPH EVK JURXS FRP 50 1 9001396429 9001396429 980801 ...