In the dishwasher:
Note: 

If the metal mesh grease filters are cleaned in the 

dishwasher, slight discolouration may occur. This has no effect 

on the function of the metal mesh grease filters.

Do not clean heavily soiled metal mesh grease filters together 

with utensils.

Place the metal mesh grease filters loosely in the dishwasher. 

The metal mesh grease filters must not be wedged in.

Removing the activated charcoal filter (only in 

circulating-air mode)

In order to guarantee efficient odour filtration, the filter must be 

serviced regularly.
The activated charcoal filters must be replaced at least every 

4 months.

Notes

The activated charcoal filters are not included in the delivery. 

The activated charcoal filters can be obtained from specialist 

retailers, from our after-sales service or from the Online Shop.

The activated charcoal filters cannot be cleaned or 

reactivated.

1.

Remove the metal grease filters.

2.

Remove the activated charcoal filter from the retainer.

3.

Guide the activated charcoal filter around the motor.

4.

Take out the activated charcoal filter.

5.

Clean the appliance.

Fitting the activated charcoal filter (only in 

circulating-air mode)

1.

Insert the activated charcoal filter into the extractor hood.

2.

Guide the activated charcoal filter around the motor.

3.

Carefully slide the new activated charcoal filter into the 

retainer.

4.

Install the metal grease filters.

Installing the metal mesh grease filter

1.

Insert the metal mesh grease filter.
While doing this, place the other hand under the metal mesh 

grease filter.

2.

Fold the metal mesh grease filter upwards, locking it in place.

Removing the activated charcoal filter (only in 

circulating-air mode)

In order to ensure adequate odour removal, you must replace 

the activated charcoal filter regularly.
With normal levels of use (1 to 2 hours a day), the activated 

charcoal filter must be replaced at least every 12 months.

Notes

The activated charcoal filter is not included with the 

appliance.The activated charcoal filter is available from 

specialist retailers, from our after-sales service or from our 

online shop.

The activated charcoal filter cannot be cleaned or reactivated.

Activated charcoal filters do not contain any harmful 

substances and can be disposed of with your normal 

household waste.

Summary of Contents for LB59584M

Page 1: ... en Instruction manual Extractor hood LB59584M LB79585M LB89585M LB79585MGB ...

Page 2: ......

Page 3: ...d and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards Children must not play with on or around the appliance Children must not clean the appliance or carry out general mainte...

Page 4: ...oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or catch fire Only operate the gas burners with cookware on them Risk of fire Operating several gas burner...

Page 5: ... require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Put the lid on to reduce cooking steam and condensation Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating ai...

Page 6: ... and switches off automatically after 30 minutes 1 Set the fan level 2 Press and hold the 2x button Fan run on is activated The button for this level flashes green Interval ventilation With interval ventilation the ventilation system switches on automatically at the lowest level for 10 minutes every hour The interval ventilation switches off after 24 hours Switching on Press and hold the 3J button...

Page 7: ...metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning a...

Page 8: ...out the activated charcoal filter 5 Clean the appliance Fitting the activated charcoal filter only in circulating air mode 1 Insert the activated charcoal filter into the extractor hood 2 Guide the activated charcoal filter around the motor 3 Carefully slide the new activated charcoal filter into the retainer 4 Install the metal grease filters Installing the metal mesh grease filter 1 Insert the m...

Page 9: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service LED lights Defective LED lights must only be replaced by the manufacturer their customer service department or a licensed technician electrician Malfunction table Fault Possible cause Solution The appliance does not work The plug is not plugged into the mains...

Page 10: ... in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You ca...

Page 11: ......

Page 12: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 9001408505 9001408505 990830 ...

Reviews: