background image

11

Prior to installation

Circulating-air mode

With activated carbon filter if exhaust-air
mode is not possible.

The complete installation set can be

obtained 

from specialist

outlets.

The corresponding accessory numbers can
be found at the end of these operating
instructions.

Preparing the wall

The wall must be flat and perpendicular.

Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.

Electrical connection

This is what you have to do:

1.

Connect the green and yellow (Earth)

wire to the terminal in the plug marked
‘E’ or with the symbol (       ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 

terminal marked ‘L’, or coloured red.

The extractor hood 

should only be

connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
behind the chimney panelling.

The earthed socket should be 
connected via its own circuit.

If the earthed socket is no longer 
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.

If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his 
customer service or a similarly qualified
person in order to prevent serious injury to
the user.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.

This extractor hood corresponds to EC
regulations concerning RF interference
suppression.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.

Weight in kg:

We reserve the right to construction changes within the 
context of technical development.

Exhaust air

Recirculating air

12,5

0

60 cm

13,5

13,0

0

70 cm

14,0

13,9

0

90 cm

14,9

14,8

100 cm

15,8

16,0

120 cm

17,5

Summary of Contents for LC45 Series

Page 1: ...LC 75 LC 90 LC 45 Operatingand installationinstructions ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ...f poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and ovens Unrestrict...

Page 4: ...or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user Dispose of packaging materials properly see Installation instructions This...

Page 5: ...but the efficiency of the extractor hood can also be adversely affected Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place is reduced Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be clea...

Page 6: ... the metal filters see Removing and inserting the metal grease filters 2 Insert an activated carbon filter on the right and left of the fan motor and rotate the filters until they lock into position 1 2 Filters and maintenance 2 Clean the filters 3 Insert the clean filters back into the hood Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more an...

Page 7: ...rt but wipe off with a damp cloth When cleaning the grease filters remove grease deposits from accessible parts of the housing This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency Note Do not use alcohol spirit on plastic surfaces as dull marks may appear Caution Ensure that the kitchen is ade quately ventilated Avoid naked flames Clean the o...

Page 8: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Page 9: ...e supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal int...

Page 10: ...m level and there will be an increase in noise The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Round pipes Internal diameter Flat ducts Cross section l 100 mm 179 cm2 l 120 mm 11...

Page 11: ...ly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator must be installed in the household circuit A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles Such devices include circuit breakers and contactors If the connecting cable for this appliance is damaged the cable must ...

Page 12: ...tric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 5 holes dia 8 mm for the extractor hood and 4 holes dia 8 mm for the brackets for fixing the flue ducts and insert wall plugs flush with the wall Note Take into account any special accessories that are going to be fitted 5 Screw on the 2 brackets for fixing the upper and lower ...

Page 13: ...revent scratching the upper duct when pushing on the lower duct cover the edge of the lower duct with the installation template or other protective material Then screw the flue duct to the sides of the fixing bracket with 2 short screws Before tightening the 2 screws align the flue duct 14 Re insert the grease filter see operating instructions 1 2 11 Stainless steel model Remove the protective fil...

Page 14: ...14 Notes ...

Page 15: ...15 353121 1 2 1 LZ 51450 ...

Page 16: ...9000 159 007 Printed in Germany 0306 Es Siemens Electrogeräte GmbH Family Line 01805 2223 3 0 12 min DTAG Siemens Hausgeräte Besuchen Sie uns im Internet http www siemens de hausgeraete ...

Reviews: