background image

 Customer service  

en

11

INSTALLATION INSTRUCTIONS

Installation instructions

This appliance is installed on the wall.

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 

If the extractor hood is to be operated in air-

recirculation mode, an optional accessory must be 

fitted. To do this, refer to the installation instructions 

provided.The flue duct does not need to be fitted for 

air-recirculation mode.

For additional optional accessories, refer to the 

installation instructions provided.

The surfaces of the appliance are sensitive. Avoid 

damaging them during installation. 

$

%

$ %

"

PLQ
PP

PLQ PP
PD[PP

PLQ
PP

PLQ PP
PD[PP

•PP

•PP

#

•PP

•PP

PP

PP

Summary of Contents for LC67KHM60

Page 1: ...Register your product online siemens home bsh group com welcome en QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...allation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance m...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throu...

Page 6: ...e symbol Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the symbol powerBoost position On some appliances the glass front can be ad...

Page 7: ...ll purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front fully 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 3 Take the metal grease filt...

Page 8: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Plac...

Page 9: ... appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed custom...

Page 10: ...filter for starter set LZ10AKU00 LZ10AKA00 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set LZ10AKT00 LZ10AKA00 Starter set for air recirculation mode with filter that can be regenerated flat hood with chimney LZ10AFS00 Starter set for air recirculation mode with filter that can be regenerated angled hood with chim ney LZ10AKS00 Starter set for ...

Page 11: ...o be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP P...

Page 12: ...tion Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire...

Page 13: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 14: ... KGeneral information Generalinformation Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 15: ... hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place...

Page 16: ...ng without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 17: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Page 18: ...en Installation 18 ...

Page 19: ...Installation en 19 ...

Page 20: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001158553 9001158553 960901 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...