background image

  Important safety information   

en

15

:

Warning

Risk of death!

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room if 

the appliance is being operated in exhaust air 

mode at the same time as room air-dependent 

heat-producing appliance is being operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of injury!

Changes to the electrical or mechanical 

assembly are dangerous and may lead to 

malfunctions. Do not make any changes to 

the electrical or mechanical assembly. 

:

Warning

Hazard due to magnetism!

Permanent magnets are inserted in the 

appliance front. They may affect electronic 

implants, e.g. heart pacemakers or insulin 

pumps. Wearers of electronic implants must 

stay at least 10 cm away from the appliance 

front.

Summary of Contents for LC91KWP60

Page 1: ...Register your product online siemens home bsh group com welcome en QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...llation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance ma...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ...nel Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the A symbol to select the fan setting you require Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches back to the fan setting that was set beforeha...

Page 7: ...or air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the and symbols at the same time until 2 lights up for air recirculation mode filters that cannot be regenerated Repeatedly touching and holding this button combination makes 3 light up for air recirculation mode filte...

Page 8: ...seconds the extractor hood automatically switches back to the fan setting that was set beforehand Switching off If you want to end the Boost function before the preset time expires touch the symbol powerBoost position On some appliances the glass front can be adjusted to an intermediate position powerBoost position The powerBoost position can be used for eliminating particularly strong cooking sme...

Page 9: ...ely 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement When the signal tone is activated will be lit Switching off Touch and hold the and symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement When the signal tone is deactivated will be lit 2Cleaning and maintenance Cleaningandmaint...

Page 10: ...y water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled ...

Page 11: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Page 12: ... in the accessory E no FD no After sales serviceO GB 0344 892 8999 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Z Nr FD E Nr Type Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set LZ10AFU00 LZ10AFA00 Starter set for air recirculation mode flat hood without chimney Easy ...

Page 13: ...erated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP PLQ PP P...

Page 14: ...on location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The specifi...

Page 15: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 16: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 17: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 18: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 19: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Page 20: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001158922 9001158922 970606 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Reviews: