background image

en

    General information

16

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Risk of electric shock!

It must always be possible to disconnect 

the appliance from the power supply. The 

appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug can no longer 

be reached after installation, an energy-

isolating device in the phases must be 

provided in the permanent electrical 

installation in accordance with the 

installation regulations. The permanent 

electrical installation must only be wired by 

a professional electrician. We recommend 

installing a residual-current circuit breaker 

(RCCB) in the appliance's power supply 

circuit.

:

Warning

Risk of electric shock!

Incorrect repairs are dangerous. Repairs may 

only be carried out and damaged power 

cables replaced by one of our trained after-

sales technicians. If the appliance is defective, 

unplug the appliance from the mains or switch 

off the circuit breaker in the fuse box. Contact 

the after-sales service.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General information

Checking the wall

The wall must be level, vertical and adequately load-

bearing.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The maximum weight of the extractor hood is 

40 kg

.

Electrical connection

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection information can be found on 

the rating plate on the top of the appliance.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the appliance 

from the power supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. If the plug can no longer be reached 

after installation, an energy-isolating device in the 

phases must be provided in the permanent electrical 

installation in accordance with the installation 

regulations. The permanent electrical installation must 

only be wired by a professional electrician. We 

recommend installing a residual-current circuit breaker 

(RCCB) in the appliance's power supply circuit.

Summary of Contents for LC91KWP60

Page 1: ...Register your product online siemens home bsh group com welcome en QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...llation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance ma...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ...nel Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the A symbol to select the fan setting you require Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches back to the fan setting that was set beforeha...

Page 7: ...or air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the and symbols at the same time until 2 lights up for air recirculation mode filters that cannot be regenerated Repeatedly touching and holding this button combination makes 3 light up for air recirculation mode filte...

Page 8: ...seconds the extractor hood automatically switches back to the fan setting that was set beforehand Switching off If you want to end the Boost function before the preset time expires touch the symbol powerBoost position On some appliances the glass front can be adjusted to an intermediate position powerBoost position The powerBoost position can be used for eliminating particularly strong cooking sme...

Page 9: ...ely 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement When the signal tone is activated will be lit Switching off Touch and hold the and symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement When the signal tone is deactivated will be lit 2Cleaning and maintenance Cleaningandmaint...

Page 10: ...y water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled ...

Page 11: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Page 12: ... in the accessory E no FD no After sales serviceO GB 0344 892 8999 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Z Nr FD E Nr Type Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set LZ10AFU00 LZ10AFA00 Starter set for air recirculation mode flat hood without chimney Easy ...

Page 13: ...erated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP PLQ PP P...

Page 14: ...on location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The specifi...

Page 15: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 16: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 17: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 18: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 19: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Page 20: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001158922 9001158922 970606 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Reviews: