6
Operating the appliance
These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note:
Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Control panel
Setting the fan
Note:
Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on
1.
Press the 1 button.
The fan starts at level 1.
2.
Press button 1, 2, 3 or
&
to set another fan level.
The
F
button and the button for this fan level light up.
Switching off
Press the
F
button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
1.
Press the
&
button.
The
F
button lights up and the
&
button flashes. Intensive
mode is activated.
2.
Press the
&
or
F
button.
Intensive mode is deactivated.
Note.
Intensive mode runs for six minutes. Once this time has
elapsed, the appliance switches back to the fan level that was
previously set.
Interval ventilation
With interval ventilation, the ventilation system switches on
automatically for 10 minutes every hour. The appliance
switches off after 24 hours.
Note:
If the intensive mode or fan run-on are activated, the
interval ventilation is not available.
1.
Press the
J
button.
The
F
and
J
buttons light up. The interval ventilation is
switched on. The fan starts at level 1.
2.
Press the
J
or
F
button.
The interval ventilation is switched off.
Fan run-on time
Note:
If intensive mode or interval ventilation is activated, fan
run-on will not be available.
1.
Select the fan setting.
2.
Press the
+
button.
The
F
and
+
buttons light up. The fan will continue to run at
this setting for 15 minutes and then switch off automatically
once this time has elapsed. If the lighting is switched on, this
will also be switched off once the run-on time has elapsed.
3.
Press the
+
or
F
button.
The fan run-on will end before the remaining run-on time has
elapsed.
Lighting
The lighting can be switched on and off independently of the
ventilation system.
Press the
=
button.
The
=
button lights up.
Setting the brightness
1.
Press and hold the
=
button for two seconds.
The brightness is reduced.
2.
Press the
=
button.
The maximum brightness is restored.
Saturation display
When the metal grease filters or activated charcoal filters are
saturated, the corresponding symbol will flash:
■
Metal grease filter:
2
■
Activated charcoal filter:
3
The metal grease filters should now be cleaned or the activated
charcoal filter replaced; see the section on
Cleaning and
maintenance
.
Resetting the saturation displays
1.
Switch off the motor and the lighting.
2.
Press and hold the
J
button.
The
F
button flashes three times. The saturation indicator for
the metal grease filter and for the activated charcoal filter is
reset.
Switching over the display for circulating-air mode
For air recirculation, the electronic control display must be
switched over accordingly:
1.
Check whether the extractor hood is connected and switched
off.
2.
Press and hold the
&
button until the
F
button flashes twice.
The electronic control is switched over to air recirculation.
Switching over the display for exhaust air mode
1.
Check whether the extractor hood is connected and switched
off.
2.
Press and hold the
&
button until the
F
button flashes once.
The electronic control is switched over to air extraction.
Explanation
=
Switches on the lighting
F
Switches off the fan
1
Switches on fan setting 1
2
Switches on fan setting 2
3
Switches on fan setting 3
&
Switches on intensive mode
J
Switches on interval ventilation
x
Switches on the fan run-on
-
[