background image

en

    Cleaning and maintenance

12

3.

Now close one of the fan flaps, slightly lift it out of 

the holder at the front and then slide it out towards 

you. Repeat the process with the other fan flap.

Caution!

Risk of damage when lifting out and setting down 

the fan flaps.Pull the fan flaps up to remove them 

and make sure that you do not scratch the surfaces 

of the appliance.

4.

Once the fan flaps and filter have been removed, 

clean the inside of the appliance.

5.

Once you have finished cleaning the appliance, refit 

the fan flaps and the magnetic strip and insert the 

metal grease filter.

Cleaning the metal mesh grease filters

Notes

Do not use any aggressive, acidic or alkaline 

cleaning agents.

When cleaning the metal mesh grease filters, also 

clean the holder for the metal mesh grease filters in 

the appliance using a damp cloth.

The metal mesh grease filters can be cleaned in the 

dishwasher or by hand.

By hand:

Note: 

You can use a special grease solvent for 

stubborn dirt. It can be ordered via the Online Shop.

Soak the metal mesh grease filters in a hot soapy 

solution. 

Clean the filters with a brush and then rinse them 

thoroughly.

Leave the metal mesh grease filters to drain.

In the dishwasher:

Note: 

Slight discolouration may occur if the metal 

grease filters are cleaned in the dishwasher. This has 

no effect on the performance of the metal grease filters.

Do not clean heavily soiled metal grease filters 

together with cookware.

Place the metal grease filters in the dishwasher, 

leaving plenty of space around them. The metal 

grease filters must not be wedged in.

Place the metal grease filters in the dishwasher with 

the opening facing down.

Wash the fan flaps and gas deflector by hand, and 

not in the dishwasher.

Installing the metal mesh grease filter

Position the metal grease filter correctly and insert it.

Note: 

Place the filter into the groove.

Replacing or regenerating the activated charcoal 

filters

Activated charcoal filters trap the odour-causing 

compounds in cooking smells. They are only used for 

circulating-air mode.

Notes

The air recirculation module and activated charcoal 

filters are not included with the appliance. The air 

recirculation module and activated charcoal filters 

are available from specialist retailers, from our after-

sales service or from our online shop.

Only use genuine replacement filters. This will 

ensure that the appliance performs optimally.

Refer to the printed supplement for information 

about the regenerability of the activated charcoal 

filters and about replacing them.

Resetting the saturation displays

Once you have cleaned or replaced the relevant filters, 

reset the saturation indicator so that the symbols go 

out.
Press and hold the 

A

 button until 

 flashes three times 

on the display panel.The saturation indicators for the 

metal grease filter and the activated charcoal filter have 

now been reset.

Summary of Contents for LF16VA570

Page 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH FRP ZHOFRPH Instruction manual Extractor hood LF16VA570 LF16VA570B ...

Page 2: ......

Page 3: ...e works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres abo...

Page 4: ...ther technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease...

Page 5: ...Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Electromagnetic hazards This appliance complies with safety and electromagnetic compatibility standards However people with pacemakers or insulin pumps must refrain from using this appliance It is impossible to ensure that all of these devices available on the market comply with current electromagneti...

Page 6: ...ronmentalprotection Your new appliance is particularly energy efficient Here you can find tips on how to save even more energy when using the appliance and how to dispose of your appliance properly Saving energy Only switch the ventilation on when necessary You do not need to switch the ventilation on when cooking something for a short time that does not have a strong smell Select a fan setting ac...

Page 7: ...circulation mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop 1Operating the appliance Operatingtheappliance Warning Risk of burns The appliance will become hot during operation Allow it to cool down before touching the fan flaps and other components Note Switch on the extra...

Page 8: ...ng over the display for exhaust air mode 1 Check whether the extractor hood is connected and switched off 2 Press and hold the button until flashes once on the display panel This will switch the electronic controller over to air extraction mode Switching the appliance on and off Note Before you switch on the appliance open both fan flaps by pressing on them lightly Note Always adjust the setting a...

Page 9: ... from collecting in the table ventilation and in the air recirculation in the cabinet and toe kick The table ventilation then switches itself off automatically Switching on Notes If intensive mode has been activated the run on function is not available The fan flaps must remain closed while the run on function is active 1 Select the fan setting 2 Press the x button The LED û beside the x symbol wi...

Page 10: ...e filter The filter must be serviced regularly in order to guarantee efficient filtration of odours and grease Metal grease filter The metal grease filters must be cleaned every 100 operating hours or at least every two months Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filte...

Page 11: ...ith two fingers at its edge and remove it Caution Risk of damage when lifting out and setting down the fan flaps Pull the metal grease filter straight up to remove it and make sure that you do not scratch the surfaces of the appliance 3 Clean the metal grease filter and filter cover Cleaning the inside of the appliance You can remove the fan flaps in order to clean the appliance thoroughly 1 Open ...

Page 12: ...mance of the metal grease filters Do not clean heavily soiled metal grease filters together with cookware Place the metal grease filters in the dishwasher leaving plenty of space around them The metal grease filters must not be wedged in Place the metal grease filters in the dishwasher with the opening facing down Wash the fan flaps and gas deflector by hand and not in the dishwasher Installing th...

Page 13: ...ta of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Problem Possible cause Solution The appliance does not work The plug is not plugged into the mains Connect the...