background image

en

    Important safety information

4

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Risk of fire! 

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire! 

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire! 

Fatty deposits in the grease filter may catch 

fire. If the appliance is to be operated next 

to a gas-fired appliance, a gas deflector 

must be fitted before you begin cooking. 

The gas deflector improves extraction for 

gas-fired appliances. The gas deflector 

prevents small flames from being blown out 

by the draught. 

Risk of fire! 

Fatty deposits in the grease filter may catch 

fire. Operating a gas wok gives rise to a 

great deal of heat. The appliance must not 

be combined with a gas wok.

:

Warning – Risk of burns! 

The accessible parts become very hot when in 

operation. Never touch hot parts. Keep 

children at a safe distance.

Summary of Contents for LF16VA570

Page 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH FRP ZHOFRPH Instruction manual Extractor hood LF16VA570 LF16VA570B ...

Page 2: ......

Page 3: ...e works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres abo...

Page 4: ...ther technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease...

Page 5: ...Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Electromagnetic hazards This appliance complies with safety and electromagnetic compatibility standards However people with pacemakers or insulin pumps must refrain from using this appliance It is impossible to ensure that all of these devices available on the market comply with current electromagneti...

Page 6: ...ronmentalprotection Your new appliance is particularly energy efficient Here you can find tips on how to save even more energy when using the appliance and how to dispose of your appliance properly Saving energy Only switch the ventilation on when necessary You do not need to switch the ventilation on when cooking something for a short time that does not have a strong smell Select a fan setting ac...

Page 7: ...circulation mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop 1Operating the appliance Operatingtheappliance Warning Risk of burns The appliance will become hot during operation Allow it to cool down before touching the fan flaps and other components Note Switch on the extra...

Page 8: ...ng over the display for exhaust air mode 1 Check whether the extractor hood is connected and switched off 2 Press and hold the button until flashes once on the display panel This will switch the electronic controller over to air extraction mode Switching the appliance on and off Note Before you switch on the appliance open both fan flaps by pressing on them lightly Note Always adjust the setting a...

Page 9: ... from collecting in the table ventilation and in the air recirculation in the cabinet and toe kick The table ventilation then switches itself off automatically Switching on Notes If intensive mode has been activated the run on function is not available The fan flaps must remain closed while the run on function is active 1 Select the fan setting 2 Press the x button The LED û beside the x symbol wi...

Page 10: ...e filter The filter must be serviced regularly in order to guarantee efficient filtration of odours and grease Metal grease filter The metal grease filters must be cleaned every 100 operating hours or at least every two months Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filte...

Page 11: ...ith two fingers at its edge and remove it Caution Risk of damage when lifting out and setting down the fan flaps Pull the metal grease filter straight up to remove it and make sure that you do not scratch the surfaces of the appliance 3 Clean the metal grease filter and filter cover Cleaning the inside of the appliance You can remove the fan flaps in order to clean the appliance thoroughly 1 Open ...

Page 12: ...mance of the metal grease filters Do not clean heavily soiled metal grease filters together with cookware Place the metal grease filters in the dishwasher leaving plenty of space around them The metal grease filters must not be wedged in Place the metal grease filters in the dishwasher with the opening facing down Wash the fan flaps and gas deflector by hand and not in the dishwasher Installing th...

Page 13: ...ta of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Problem Possible cause Solution The appliance does not work The plug is not plugged into the mains Connect the...

Page 14: ...en Accessories 14 _Accessories Accessories Special accessories Accessories Order number Air recirculation module for LF16VA570 LZ58000 Accessories Order number Gas deflector for LF16VA570 LZ58010 ...

Page 15: ...6 ...

Page 16: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 6 DXVJHUlWH PE DUO HU 6WU VLHPHQV KRPH FRP 0 QFKHQ 50 1 9001175272 9001175272 960725 ...

Reviews: