background image

en

    General information

12

:

Warning

Risk of fire!

Grease deposits in the grease filter may catch 

fire. The specified safety distances must be 

observed in order to prevent an accumulation 

of heat. Observe the specifications for your 

cooking appliance. If gas and electric hobs 

are operated together, the largest specified 

distance applies.

Only one side of the appliance may be 

installed directly next to a high-sided unit or a 

wall. The distance between the appliance and 

wall or high-sided unit must be at least 50 

mm. 

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the 

appliance from the power supply. The 

appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug can no longer be 

reached after installation, an energy-isolating 

device in the phases must be provided in the 

permanent electrical installation in accordance 

with the installation regulations. The 

permanent electrical installation must only be 

wired by a professional electrician. We 

recommend installing a residual-current circuit 

breaker (RCCB) in the appliance's power 

supply circuit.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General information

Exhaust air mode

:

Warning

Risk of death!

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The appliance manufacturer does not provide any 

warranty for faults attributable to the pipe section.

The appliance achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long, rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

150 mm diameter, approx. 177 cm

2

120 mm diameter, approx. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for different pipe diameters.

‘

‘

‘

‘

Summary of Contents for LI64MA530

Page 1: ...Register your product online siemens home bsh group com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...tallation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance ...

Page 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Page 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Page 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through ...

Page 6: ...button to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button until all of the LEDs in the display light up The intensive setting is activated After approx six minutes the electronics automatically reduce the fan to a lower setting If you wan...

Page 7: ...tal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse...

Page 8: ...es replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Replacing bulbs These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Warning Risk o...

Page 9: ...Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by t...

Page 10: ...ssible that individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm 2x 2x ...

Page 11: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 12: ...al installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flu...

Page 13: ...end installing a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking ap...

Page 14: ...re the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the two angle brackets to the appliance Ensure that the screws are positioned correctly ª Screw in the screws until 8 mm of the threaded section is still protruding 5Installation InstallationInstallation 1 Use the angle brackets to hang the...

Page 15: ...ales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filter pull out can be changed Spacers are included with these appliances in order to set the appliance s handle strip so that it is flush with the fitted unit 1 Pull the filter pull out forwards 2 Shorten...

Page 16: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001057428 9001057428 960915 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Reviews: