en
General information
12
Electrical connection
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection data can be found on the
rating plate inside the appliance; to do this, remove the
metal mesh grease filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
:
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the power supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed. If the plug can no longer be reached
after installation, an energy-isolating device in the
phases must be provided in the permanent electrical
installation in accordance with the installation
regulations. The permanent electrical installation must
only be wired by a professional electrician. We
recommend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.
Preparing the units
■
The fitted unit must be level and have sufficient load-
bearing capacity.
■
The max. weight of the extractor hood is 18 kg.
Appliance dimensions and safety clearances
■
Observe the appliance's dimensions.
■
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
The fitted unit must be heat-resistant up to 90 °C.The
fitted unit must still be sturdy after the cut-outs have
been made.
To install the extractor hood in a wall-hanging
cupboard, the extractor hood must be provided with the
following dimensions:
1.
Make the cut-out for the exhaust air pipe. To do this,
make an opening in the top or back panel of the
fitted unit with an additional recess for the power
cord.
2.
If the cabinet base is in place, remove it. Mark the
fastening points on the inside of the cabinet and use
a bradawl to make indentations where the holes are
to be. To help you mark the fastening points, use the
fastening piece provided.
Width
600 mm
Depth
Min. 320 mm
Depth
Min. 350 mm with lowering frame
Height
Min. 420 mm
Height
Min. 600 mm with CleanAir air recirculation
module
Wall thickness
16 mm or 19 mm
PP
PP
PLQ
PP