Note: 

The extractor hood's housing can be concealed 

within the upper cabinet. In doing so, you must observe 

the following:

The intermediate floor must not be placed on the 

extractor hood's housing.

The front panel must not be secured to the housing.

Access must be available in order to change the 

filter and for the after-sales service.

Appliance width 90 cm:

You must also screw the appliance to the wall-hanging 

cupboards either side of it.

Changing the filter pull-out's limit stop

On some versions of the appliance, the limit stop for the 

filter pull-out can be changed. Spacers are included 

with these appliances in order to position the 

appliance's handle strip flush with the fitted unit.

1.

Pull the filter pull-out towards you.

2.

Shorten the spacer to the required dimension and 

insert it into the slot specified.

Connecting the pipes

Note: 

If an aluminium pipe is used, smooth the area 

where it is to be connected before you connect it.

Exhaust air pipe, dia. 150 mm (recommended size)

Fit the exhaust air pipe directly to the air-pipe connector 

and seal the joint.

Exhaust air pipe, dia. 120 mm

1.

Fit the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Seal both joints appropriately.

Removing the appliance

1.

Disconnect the electrical connection.

2.

Disconnect the pipes.

3.

Remove the metal grease filter.

4.

Remove the protective caps from the fastening 

elements.

5.

Remove the appliance; see section entitled 

"Removing the appliance".

Summary of Contents for LI67SA530A

Page 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH EVK JURXS FRP ZHOFRPH en Instructions for installation and use Extractor hood ...

Page 2: ...allation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance m...

Page 3: ...ase consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 mont...

Page 4: ...the direction of the grain only Do not use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope 7Environmental protection EnvironmentalprotectionYour new appliance ...

Page 5: ...n fumes Control panel Setting the fan Switching on Pull out the filter pull out and press the button The fan starts at setting 2 Press the or button to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button until all of the LEDs in the display l...

Page 6: ...tal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse...

Page 7: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Replacing bulbs These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Warning Risk ...

Page 8: ...rged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your ...

Page 9: ...sible that individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm PP PP ...

Page 10: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 11: ...al installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flu...

Page 12: ...liance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking appliances specify a different distance the largest distance must a...

Page 13: ...to the filter pull out This handle strip can be one that is provided with the appliance or one that is available as an accessory 1 Use the screws provided to secure the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 5Installation InstallationSliding the appliance up into place 1 Slide the appliance up...

Page 14: ...he housing along with the spring Pull gently on the fastening bolt before you do this take hold of the appliance from beneath with the other hand ª 3 Carefully remove the appliance 4 Screw in the filler strip fully 5 Push in the fastening bolt and turn it 90 Note The fastening pieces on the left and right of the appliance must be able to move Final fitting stage 1 Slide the appliance up into place...

Page 15: ... the appliance s handle strip flush with the fitted unit 1 Pull the filter pull out towards you 2 Shorten the spacer to the required dimension and insert it into the slot specified Connecting the pipes Note If an aluminium pipe is used smooth the area where it is to be connected before you connect it Exhaust air pipe dia 150 mm recommended size Fit the exhaust air pipe directly to the air pipe con...

Page 16: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 6 DXVJHUlWH PE DUO HU 6WU 0 QFKHQ VLHPHQV KRPH EVK JURXS FRP 50 1 9001057529 9001057529 960915 ...

Reviews: