background image

 

 

MDS D423 

4

 

C79000-G8976-C319-01, 05/2013 

 

Note 
Range in a non-metallic environment 
The MDS D423 is optimized for use in a metallic environment. If the MDS D423 is used in a non-metallic environment, this 

results in a reduced range.  

 

5  

 

Technical specifications 

Table 5-1 

Technical specifications of MDS D423 

Memory size 

2048 bytes 

Memory configuration 

 

Serial number 

 

Configuration memory 

 

Application memory 

 

 

8 bytes (fixed code) 

 

40 bytes 

 

2000 bytes 

Storage technology 

FRAM 

Memory organization 

FRAM, 2048 bytes gross 

2000 bytes net 
(when using the OPT area, 16 bytes of it must be subtracted in 8 

byte blocks) 

Report 

ISO 15693 

Data retention (at +40 °C) 

10 years 

MTBF (at +40 °C) 

2 x 10

6

 hours 

Read cycles 

Unlimited 

Write cycles (at +40 °C) 

> 10

10

 

Read/write distance (S

g

See section "Field data (Page 3)." 

Mounting on metal 
Mounting in metal 

Yes 
yes, with 10 mm clearance all round 

Power supply 

inductive power transmission (without battery) 

Degree of protection to EN 60529 

IP68 

1)

 

IPx9K 

2)

 

Pressure resistance 

 

low pressure resistant 

3)

 

 

high pressure resistant (see degree of protection IPx9K) 

Shock according to EN 60721-3-7, Class 7M3  

Total shock response spectrum, Type II 

50 g 

4)

 

Vibration-resistant to EN 60721-3-7, Class 7M3 

20 g 

4)

 

Torsion and bending load 

Not permissible 

Enclosure 

 

Dimensions (D x H) 

 

Color 

 

Material 

 

 

30 mm (+0.2/-0.5) x 8 mm (-0.5) 

 

Black 

 

Plastic PPS, silicone-free 

Fixing 

Countersunk screw, thread M4 

5)

 

Tightening torque 

≤ 1 Nm 

Summary of Contents for MDS D423

Page 1: ...rning notice representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning not...

Page 2: ... or containers production automation Memory FRAM 2048 bytes gross 2000 bytes net Installation Can be mounted in and on metal 2 Ordering data Table 2 1 Ordering data of MDS D423 Order number MDS D423 6GT2600 4AA00 3 Mounting on metal Mounting on metal Direct mounting of the MDS D423 on metal is possible 0HWDO DWD PHPRU Figure 3 1 Mounting the MDS D423 on metal ...

Page 3: ...RF240R 2 35 mm 40 mm 40 mm 100 mm RF260R 2 40 mm 45 mm 45 mm 200 mm RF310R as of AS D 2 35 mm 46 mm 30 mm 100 mm RF340R 2 40 mm 55 mm 60 mm 200 mm RF380R 5 75 mm 90 mm 80 mm 500 mm Table 4 2 Field data of the MDS D423 flush mounting in metal 1 Operating distance Sa Limit distance Sg Transmission window Lx Ly Minimum distance from MDS to MDS RF210R 2 8 mm 11 mm 20 mm 40 mm RF220R 2 20 mm 23 mm 30 m...

Page 4: ...eport ISO 15693 Data retention at 40 C 10 years MTBF at 40 C 2 x 106 hours Read cycles Unlimited Write cycles at 40 C 1010 Read write distance Sg See section Field data Page 3 Mounting on metal Mounting in metal Yes yes with 10 mm clearance all round Power supply inductive power transmission without battery Degree of protection to EN 60529 IP68 1 IPx9K 2 Pressure resistance low pressure resistant ...

Page 5: ...r MDS D423 Trademarks All names identified by are registered trademarks of Siemens AG The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be p...

Reviews: