7ML19981FY01
Heated Enclosure – INSTRUCTION MANUAL
Page 7
mmm
mm
Wiring
Wiring
Vertical Mount
Warning: Hazardous voltage present on terminal during
operation.
Notes:
• Recommended torque on terminal clamping screws: 0.56 – 0.79 Nm (5–7 in/lbs)
• The equipment must be protected by a 15 A fuse, or a circuit breaker in the
building installation.
• A circuit breaker or switch in the building installation, marked as the disconnect
switch, must be in close proximity to the equipment and within easy reach of
the operator.
• Do not connect level monitor to enclosure terminals.
Important: All safety and operating information in this manual apply to
the Heated Enclosure only. Consult instrument manual for
safety and operating instructions.
COVER NOT SHOWN
115Vac, 120VA
L1
L1
L2/N
L2/N
thermostat
Milltronics
Level
Monitor
strip heater
terminal block
ground lug terminal
enclosure
level monitor cable entry:
refer to individual product
for power consumption
.
Note: do not wire
level monitor to
Heated Enclosure
terminal.
Heater Box.fm Page 7 Wednesday, April 24, 2002 9:47 AM