7ML19985CW01
Milltronics ILE-37 – INSTRUCTION MANUAL
Page 9
Calibration
A Test Weight is a calibration reference used to simulate a material impact force (test
rate) on the flowmeter sensing plate during the integrato span calibration. The test
weight is also used to perform a test to verify that the flowmeter sensing head is level.
The Test Rate should be 60 to 80% of the system design rate.
To determine the test rate produced by a specific test weight, calculate:
Test Rate (TPH) = Test Weight (grams)
65
1
grams/TPH
Alternatively, to determine the test weight required for a specific test rate, calculate:
Test Weight
= 65
1
grams/TPH x Test Rate (in TPH)
e.g. If the test weight used with an E-40 flowmeter is 500 grams:
Test Rate
=
500 grams
65 grams/TPH
=
7.65 TPH
LVDT Output
Zero Adjustment (if required)
1.
Connect a voltmeter across the LVDT green and yellow (or yellow and white;
hazardous LVDT) wires.
2.
With no load applied to the sensing plate, observe the V AC reading on the
voltmeter.
If the LVDT output is 0.10 ± 0.05 V AC, skip to Span Test, otherwise, proceed as follows:
a. Loosen the locknut on the LVDT threaded core.
b. Turn the core in/out of the LVDT until 0.10 ± 0.05 V AC is obtained.
c. Tighten the locknut, ensuring the measured value is maintained.
1.
Use 80 grams for A-40 flowmeters.
Note:
Use metric tons per hour (t/h) or short tons per hour (STPH) as applicable for
TPH.
Note:
Ensure the new position of the LVDT core allows free movement within the
LVDT bore.
± 0.05
± 0.05
0.100
LVDT
LVDT core
moving beam
locknut
increase
decrease
To Integrator
LVDT EXC.
or LVDT
Conditioner Card
Summary of Contents for milltronics ILE-37
Page 1: ...Instruction Manual September 2003 ILE 37 milltronics ...
Page 4: ...ii ...
Page 25: ...Notes ...
Page 26: ...Notes ...
Page 27: ......