Page 10
Milltronics ILE-37 – INSTRUCTION MANUAL
7ML19985CW01
Span Test
1.
Gently push the sensing head moving beam to the right. The LVDT output should
steadily increase until a level of 0.75 to 1.0 V AC is achieved.
2.
Gently push the sensing head moving beam to the left. The LVDT output should
steadily decrease until zero is reached and then start increasing again to 0.015 to
0.5 V AC.
3.
Ensure the LVDT output always returns to 0.10 ± 0.05 V AC, (to the right side of zero)
when pressure on the moving beam is released.
Sensing Head Level Test
1.
With the voltmeter still connected to the LVDT output, hang the test weight directly
off the sensing plate.
2.
Check to ensure that the LVDT output does not change by more than 0.01 V AC.
Note:
•
The LVDT core must not contact the inside of the LVDT over the range of core
travel.
•
The actual LVDT core travel during this procedure is less than 3 mm (1/8").
Note:
•
If the change is greater than 0.01 V AC, adjust the sensing head level, (refer to
“Installation” on page 4) until the change with and without the test weight on the
sensing plate is less than 0.01 V AC.
•
Remove the test weight and readjust the LVDT Output Zero, if necessary. If the
level test is performed after the integrator has been calibrated, a new integrator
Zero and Span calibration, Span Adjust, and Factoring, should be performed.
0.050
0.150
0.015
0.500
to
0.750
1.000
to
sensing
plate
changes < 0.01 V AC
test weight
voltmeter
Summary of Contents for milltronics ILE-37
Page 1: ...Instruction Manual September 2003 ILE 37 milltronics ...
Page 4: ...ii ...
Page 25: ...Notes ...
Page 26: ...Notes ...
Page 27: ......