Page 12
Milltronics ILE-37 – INSTRUCTION MANUAL
7ML19985CW01
Maintenance and Spare Parts
Maintenance
Establish a program of routine maintenance to ensure the highest achievable level of
performance. Follow good housekeeping practices in the area of the flowmeter.
Typical Maintenance Program
Spare Parts
Siemens Milltronics recommends the following spare parts be kept on hand:
•
sensing head inner gasket
•
sensing head outer gasket (base mount version only)
•
damping fluid
•
sensing plate
Contact Siemens Milltronics or your distributor for spare parts ordering information.
Unit Repair and Excluded Liability
All changes and repairs must be done by qualified personnel and applicable safety
regulations must be followed. Please note the following:
•
The user is responsible for all changes and repairs made to the device.
•
All new components must be provided by Siemens Milltronics Process
Instruments Inc.
•
Restrict repair to faulty components only
•
Do not re-use faulty components.
Frequency
Maintenance Description
Regular
Monthly
Semi-
Annual
Annual
Clean area around flowmeter
!
!
!
!
Check sensing plate surface
1
1.
Remove any material buildup in the impact area of the sensing plate.
!
!
!
!
Check damping fluid
!
!
!
Check sensing head inner gasket
!
!
!
Check sensing plate wear
!
!
!
Check test weight Rate display
!
!
Test flowmeter linearity
!
Summary of Contents for milltronics ILE-37
Page 1: ...Instruction Manual September 2003 ILE 37 milltronics ...
Page 4: ...ii ...
Page 25: ...Notes ...
Page 26: ...Notes ...
Page 27: ......