7ML19985CW01
Milltronics ILE-37 – INSTRUCTION MANUAL
Page 3
Sensing Plate
Construction
• 304 (1.4306) stainless steel
Options
• 316 (1.4404) stainless steel
• UHMW polyurethane or Ceramic Tile abrasion resistant lining
• Synergistic polymer or PFA coating for low cohesion and low friction
LVDT Conditioner Card
Power
• ± 5 V DC (typically from a Siemens Milltronics Integrator)
Ambient Temperature
• –40 to 50 °C (–40 to 122 °F)
Input
• 0 to 1.0 V AC from LVDT
Output
• 0 to 50 mV DC to Siemens Milltronics integrator; [maximum 300 m (1000 ft) separation
between conditioner card and integrator]
Approvals
• CE
Enclosure
• NEMA 4 (remote mounted unit)
Cable
For connection between LVDT Conditioner Card and Integrator
• Belden®
1
8404, 4 conductor, shielded 20 AWG (0.5 mm
2
) or equivalent, 150 m (500 ft)
maximum
• Belden 9260, 6 conductor, shielded 20 AWG (0.5 mm
2
) or equivalent, 300 m (1000 ft)
maximum
For connection between LVDT and remote LVDT Conditioner Card,
or directly between LVDT and Integrator
• Belden 8404, 4 conductor, shielded 20 AWG (0.5 mm
2
) or equivalent, 300 m (1000 ft)
maximum
1.
Belden is a registered trademark of Belden Wire & Cable Company.
Summary of Contents for milltronics ILE-37
Page 1: ...Instruction Manual September 2003 ILE 37 milltronics ...
Page 4: ...ii ...
Page 25: ...Notes ...
Page 26: ...Notes ...
Page 27: ......