802-9081.9 • INSTALLATION AND OPERATING INSTRUCTIONS • NXPLUS C • Revision 11
37/293
Description
Cellpack
50…400
EPDM 2x CTS 630A 24kV
1x CKS 630A 24kV
-
-
IEC
25…300
2x CTS 630A 24kV*
1x CKS 630A 24kV*
-
-
IEC
50…240
EPDM 1x CTS 630A 24kV
1x CTKS 630A 24kV
CTKSA
-
IEC
25…240
1x CTS 630A 24kV*
1x CTKS 630A 24kV*
CTKSA
-
IEC
Ample
25…400
EPDM 1x AQT3-15/630
1x AHT3-15/630
AHY5WZ7
-
GB/DL
35…500
1x AQT3-24/630*
1x AHT3-24/630*
AHY5WZ7
-
GB/DL
3 cables per panel and phase
Nexans
Euromold
35…300
EPDM 1x 430TB/G
2x 300PB/G
-
-
IEC, GOST, GB/DL
1x K430TB/G*
2x K300PB/G*
-
-
IEC
1x K430TB/G-CSxxx*
2x K300PB/G-CSxxx*
-
-
GOST, GB/DL
35…300
EPDM 1x 480TB/G
2x 800PB/G
-
-
IEC
1x K480TB/G*
2x K800PB/G*
-
-
IEC
50…630
EPDM 1x 484TB/G
2x 804PB/G
-
-
IEC
35…630
1x K484TB/G*
2x K804PB/G*
-
-
IEC
800…1200
EPDM 1x 489TB/G
2x 809PB/G
-
-
IEC
1x K489TB/G*
2x K809PB/G*
-
-
IEC
nkt cables 25…300
Silicon
e
1x CB 12-630
2x CC 12-630
-
-
IEC
25…500
1x CB 17,5-630
2x CC 17,5-630
-
-
GOST, GB/DL
25…300
1x CB 24-630*
2x CC 24-630*
-
-
IEC, GOST, GB/DL
185…500
Silicon
e
1x CB 24-1250-2
2x CC 24-1250-2
-
-
IEC
95…500
1x CB 24-1250-2*
2x CC 24-1250-2*
-
-
IEC
400…630
Silicon
e
1x CB 36-630(1250)
2x CC 36-630(1250)
-
-
IEC, GOST, GB/DL
1x CB 36-630(1250)* 2x CC 36-630(1250)*
-
-
IEC, GOST, GB/DL
630…1000
Silicon
e
1x CB 42-1250-3
2x CC 42-2500-3
-
-
IEC
1x CB 42-1250-3*
2x CC 42-2500-3*
-
-
IEC
Tyco
Electronics
Raychem
25…300
Silicon
e
1x RSTI-58xx
2x RSTI-CC-58xx
-
-
IEC
1x RSTI-58xx*
2x RSTI-CC-58xx*
-
-
IEC
25…300
Silicon
e
1x RSTI-58xx-CEE01
2x RSTI-CC-58xx-CEE01
-
-
GOST
1x RSTI-58xx-CEE01* 2x RSTI-CC-58xx-CEE01*
-
-
GOST
400…800
Silicon
e
1x RSTI-395x
2x RSTI-CC-395x
-
-
IEC
1x RSTI-595x*
2x RSTI-CC-595x*
-
-
IEC
400…800
Silicon
e
1x RSTI-595x-CEE01
2x RSTI-CC-595x-CEE01
-
-
GOST
1x RSTI-595x-CEE01* 2x RSTI-CC-595x-CEE01*
-
-
GOST
Cellpack
50…240
EPDM 1x CTS 630A 24kV
2x CTKS 630A 24kV
-
-
IEC
25…240
1x CTS 630A 24kV*
2x CTKS 630A 24kV*
-
-
IEC
1
At a continuous current of more than 1150 A, cable sealing ends with tin-plated, nickel-plated or silver-plated cable lugs are required.
2
Observe the actual current- and short-circuit-carrying capacity of the cables and sealing ends.
Circuit-breaker panel 630 A, 1000 A ● Switch-disconnector panel 630 A ● Disconnector panel 1000 A ● Ring-main panel 630 A ● Vacuum
contactor panel ● Circuit-breaker panel with top-rear cable connection 1250 A
1
Panel spacing 600 mm
Make
Conductor
cross-
section
2
In
su
la
ti
on
Cable T-plugs
Coupling inserts/
coupling plugs
Surge arresters with coupling inserts
According to
standard
[mm
2
]
bolted
bolted
with arresters
Coupling inserts
• GOST
(Russia, CIS)
• GB/DL (China)
12 kV
24 kV*
12 kV
24 kV*
additionally