17 LED_Keypad illumination Problems
Fault Symptoms
Customer: GRT:
Main keypad illumination does not work
Current measured failed
LED Problems
Watch for oxidation and
damaged pads of the
LED’s
caused by customer
SCRAP
- has to be send
separately to WSC
okay
Check the status of the
LED’s visually
Use the diode test
function of a multimeter
to check the status of
the diode. The typical
voltage drop on the
diode is 1.7 V when
testing the diode
function with the
multimeter.
Exchange
keypad LED’s
Continue with
higher repair level
okay
not
okay
not
okay
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
LED_ KEYPAD
Remove metal dome sheet before replace LED’s Use soldering iron to remove defective component. Avoid
excessive heat! Watch surrounding components! Resolder new component afterwards. The metal dome jip
must be used to place the metal dome sheet.
E-commerce order number:
L36840-L2056-D670
E-commerce order name:
LED AMBER
Soldering temperature:
~ 360°C Tip Temp.
IRIS Diagnose Code:
22000 Display / Background Illumination
Company Confidential
2006©BenQ