34/70
Siemens Building Technologies
Basic Documentation QAA73.110 Room unit
CE1P2284en
HVAC Products
Description
of enduser settings
10.07.2002
Depending on the type of boiler control, the room unit also displays other error codes
with the relevant error text. For detailed information, please refer to the technical
documentation of the boiler controller used.
3.18 Boiler status code
The room unit displays status codes that are generated by Siemens boiler control and
then transmitted via the OpenTherm bus. They will be cleared only when rectified.
Press the Info button to select Info line 3.
If a status code is indicated, the fault / status code symbol flashes.
When pressing the Info button, the relevant status code is displayed in clear text.
Display QAA73.110
Description of error
None
No service required
Maintenance
Boiler or burner service required
Chimney sweep
Chimney sweep function active
Controller stop
Controller stop function active
Setting Vo LF
Low-fire setting Vo is active
Setting Vo HF
High-fire setting Vo is active
Para-mode
Unit is in parameter setting mode
Floor
Unit performes floor curing function
Modem
Standby by external BMU contact
BMU
Service non-Siemens boiler control required
Other fault displays
Description
Info line 3
Effect
Status display: