Basic Documentation QAA73.110 Room unit
CE1P2284en
HVAC Products
Handling
10.07.2002
2 Handling
2.1 Engineering
•
In the main living room or reference room
•
The place of installation should be chosen so that the sensor can capture the room
temperature as accurately as possible, without being affected by direct solar
radiation or other heating or cooling sources.
•
Mounting height is about 1.5 meters above the floor
•
The unit can be fitted to most commercially available recessed conduit boxes or
directly on the wall.
2.2 Installation
•
Wall
•
Boiler control panel (with the help of clips)
•
The controller may not be exposed to dripping water
•
Permissible ambient temperature: 0...50 °C
Open the unit at the top and remove the
base from the housing front.
22
84
Z
3
6a
Fit the base to the wall with the help of
screws.
22
84
Z
3
3a
Mounting location
Mounting conditions
Wall mounting
1. step
2. step