LMR-A: Manual mode
a. WLCA- Delivery mode
10A : Keep the LMR-A in Manual mode.
10B : Keep the WLC-A in Delivery mode.
10C : Switch ON 3-Phase incoming main supply.
10D : Turn ON the rocker switch
10E : Amber LED will start blinking for a period of min 0.5 min.
10F : 0.5 min is the default setting which can vary from min 0.5 min to max.5min.
10G : After the ON-delay duration, amber LED will ON continously indicating that the incoming supply is
Healthy (Assuming incoming supply is healthy). WLC-A R LED will turn ON when P2,P3 sensors of
WLC-A are out of water.
10H : Press the green push putton for switching ON the starter.
10I : Starter gets switched ON
10J : Green LED turns ON indicating that the starter is ON.
10K : Delivery tank gets filled till the water touches the level of P3 sensor.
10L : Starter switches OFF automatically after water tank level reach P3 sensor level.
10M : Green LED turns OFF indicating that the starter is OFF.
10N : Amber LED indication remains continous ON.
10O : Switch OFF the 3-phase incoming main supply.
10P : Amber LED indication gets turned OFF indicating that there is no incoming main supply.
LMR-A: Manual mode
b. WLCA- Suction mode
10A : Keep the LMR-A in Manual mode.
10B : Keep the WLC-A in suction mode.
10C : Switch ON 3-Phase incoming main supply.
10D : Turn ON the rocker switch
10E : Amber LED will start blinking for a period of min 0.5 min.
10F : 0.5 min is the default setting which can vary from min 0.5 min to max.5min.
10G : After the ON-delay duration, amber LED will ON continously indicating that the incoming supply is
Healthy (Assuming incoming supply is healthy). WLC-A R LED will turn ON when P1,P2,P3 sensors are in water.
10H : Press the green push putton for switching ON the starter.
10I : Starter gets switched ON
10J : Green LED turns ON indicating that the starter is ON.
10K : Water gets drawn out of the suction tank till the water level goes below P2 sensor.
10L : Starter switches OFF automatically after Water level of the suction tank goes below P2 sensor.
10M : Green LED turns OFF indicating that the starter is OFF.
10N : Amber LED indication remains continous ON.
10O : Switch OFF the 3-phase incoming main supply.
10P : Amber LED indication gets turned OFF indicating that there is no incoming main supply.
Starter operation:
Installation, Maintenance & Troubleshooting guide
| Version 04
13
Summary of Contents for RAJA+ 3TE7131-1HC14-1A
Page 1: ...Installation Maintenance Troubleshooting Guide For RAJA Agriculture Starters Controllers ...
Page 6: ...4 21 Control logic diagram 6 Installation Maintenance Troubleshooting guide Version 04 ...
Page 7: ...Installation Maintenance Troubleshooting guide Version 04 4 22 Power circuit diagram 7 ...