Room temperature controllers  

CE1N3070en 

Building Technologies 

 

01.03.2010 

Override allows for temporarily overwriting the active value from the sender. 
Override responds differently depending on the radio connection (normal or fault).

 

 
 
 

Example A:

 Normal connection between sender and recipient

 

 

Press the OVERRIDE button to overwrite the value for ca. 14 minutes. The value 
then returns to the setpoint. 

 
 

Example B:

 Faulty connetion between sender and recipient

 

 

Press the OVERRIDE button to permanently overwrite the value. The value 
returns to the setpoint after the connection between sender and recipient works 
again. 

 
 

RF state 

RF LED 

Power up (First 5 seconds) 

Flash RED + GREEN (Amber) 
(5 seconds) 

Power up (After 5 seconds) 

RED 

Press OVERRIDE switch 

Flash RED + GREEN (Amber) 
(5 seconds) 

Learning period 

No LED 

Software reset 

RED 

RF receive 

GREEN 

No RF within last 25 minutes 

RED 

Manual override 
(RF receive) 

Flash GREEN 

Manual override 
(No RF receive) 

Flash RED 

 

Relay state 

Relay LED 

From OUT to ON (First 5 seconds) 

Flash YELLOW 

ON 

YELLOW 

From ON to OFF (After 5 seconds) 

Flash YELLOW 

OFF 

OFF 

 
 
 

OVERRIDE 

RF LED 

Relay LED 

Summary of Contents for RDH10RF/SET

Page 1: ...ection LCD Display 50 x 45 W x H RDH10RF transmitter battery powered RCR10 433 receiver mains powered Communication of the set is bonded ex factory Use The RDH10RF is used to control the room temperature in heating or cooling systems Typical applications Homes Residential buildings Schools Offices The controller can be used together with the following equipment Thermal valves or zone valves Combi ...

Page 2: ...e heating output is active Setpoints and information required for operating mode changeover are retained when exchanging batteries The values must be checked though Ordering Please provide the name and product number when ordering Room temperature con troller RDH10RF SET Valves and actuators are to be ordered as separate items Equipment combinations Type of unit Product number Data sheet Electromo...

Page 3: ...nd built in room temperature sensor Baseplate mounting base Removable battery compartment Fold out stand The housing engages in the baseplate and snaps on There is a reset button on the rear of the unit 1 Room temperature display in C 2 Indicates a heat request 3 Temperature setting knob 4 Battery compartment 5 Comfort temperature setpoint 6 RF TEST Indicates RF signal test 7 Indicates low battery...

Page 4: ...astic housing with LEDs and buttons Signal display LED OVERRIDE button LEARN button Relay display LED OVERRIDE LEARN button together RESET function RCR10 433 The RDH10RF is located in a plastic housing Two buttons are visible on the rear side when removing the baseplate Test button Learn button Test Learn buttons to gether RESET function RDH10RF ...

Page 5: ... electrical connections and fit and secure the receiver in compli ance with local regulations also refer to the separate mounting instructions Mount the controller on a flat wall If there are thermostatic radiator valves in the reference room set them to their fully open position For commissioning please refer to the Operating Instruction CE1B3070xx Controller and receiver are maintenance free exc...

Page 6: ...nd recipient Press the OVERRIDE button to permanently overwrite the value The value returns to the setpoint after the connection between sender and recipient works again RF state RF LED Power up First 5 seconds Flash RED GREEN Amber 5 seconds Power up After 5 seconds RED Press OVERRIDE switch Flash RED GREEN Amber 5 seconds Learning period No LED Software reset RED RF receive GREEN No RF within la...

Page 7: ...e 2004 108 EC Low voltage directive 2006 95 EC Radio equipment 1999 5 EC N 4 7 4 C tick conformity to Test standards and requirements EN 61000 6 3 AS NZS 4251 1 1999 Test standards for radio equipment AS NZS 4268 2003 Product safety Automatic electrical controls for EN 60 730 1 and household and similar use EN 60 730 2 9 Information technology equipment Safety General Requirements EN 60950 1 Gener...

Page 8: ...ions Temperature Humidity Mechanical conditions IEC 60 721 3 Class 2K3 25 70 C 93 r h Class 2M2 conformity EMC directives Low voltage directives Radio equipment 2004 108 EC 2006 95 EC 1999 5 EC Product safety Automatic electrical controls for EN 60 730 1 and household and similar use EN 60 730 2 9 Information technology equipment Safety General Requirements EN 60950 1 Generic standards Compliance ...

Page 9: ... with receiver control of a gas fired wall hung boiler Wireless room temperature controller with receiver control of atmospheric gas burner Y1 2252S04 M1 N2 T N1 T N1 2255S05 E1 N2 Wireless room temperature controller with receiver control of a heating circuit pump precontrol by manual mixing valve Wireless room temperature controller with receiver control of cooling equipment F1 Thermal reset lim...

Page 10: ...iemens Room temperature controllers CE1N3070en Building Technologies 01 03 2010 Dimensions Room temperature controller Room temperature controller mounting plate Room temperature controller with fold out stand ...

Page 11: ...11 12 Siemens Room temperature controllers CE1N3070en Building Technologies 01 03 2010 Room temperature receiver with mount ing plate ...

Page 12: ...12 12 Siemens Room temperature controllers CE1N3070en Building Technologies 01 03 2010 2007 2010 Siemens Schweiz AG Subject to change ...

Reviews: