13 Operation 

13.1 Leaving 

the 

premises 

 

The RF30-EM’s mechanical locking device only affects the outside door handle. 
The door can always be opened from the inside as usual. 

13.2 Automatic 

resetting 

 

RF30-EM has two separate resetting systems to return the lock to the locked 
position after a code has been entered. The lock is reset mechanically each time 
the door handle is used during access. The lock is also electronically reset if the 
handle is not used within 4 seconds after a card is used or a code being entered. 

This provides security against unauthorised access, since the RF30-EM can never 
accidentally be left in the unlocked position.  

13.3 Access 

blocking 

 

To thwart attempts to obtain an access code by trial and error, RF30-EM 
incorporates a blocking function to disable the unit after 12 false key presses (three 
successive incorrect 4-digit codes). The unit remains blocked until 2 correct codes 
are entered successively.  

13.4 Backup 

power 

supply 

 

When the batteries are running low. RF30-EM will flash the red LED for 3 seconds 
before opening the lock. The lock has a backup power supply that will allow the 
door to be opened 200 times or a time of two weeks has passed. 

After the door has been opened 200 times the only way to open the door is with the 
Administrator code.  

Summary of Contents for RF30-EM

Page 1: ...Siemens AG RF30 EM Codoor Configuration Manual ...

Page 2: ...ake them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him About this document This configuration manual contains instructions for installation setup configuration and operation of RF30 EM For more information about the whole wireless access control system see Si Pass Bewator Entro wireless instal...

Page 3: ...rator code 13 8 1 Present Administrator code is known 13 8 2 Present Administrator code is not known 14 9 System mode 15 9 1 Activate System mode 15 9 2 Service mode 16 9 2 1 Check signal strength A30 16 9 2 2 Check link reliability A31 16 9 2 3 Reboot the RF30 EM A32 16 9 2 4 Reconnect the network A34 16 10 Mounting 17 10 1 Technical details 17 10 2 Fitting RF30 EM to the door 18 10 2 1 Distance ...

Page 4: ...Change Group code 26 11 3 3 Delete Group code 26 11 4 Lock unlock door 27 11 5 Disable enable buzzer 27 12 Erase memory 28 13 Operation 29 13 1 Leaving the premises 29 13 2 Automatic resetting 29 13 3 Access blocking 29 13 4 Backup power supply 29 14 Command overview 30 15 Troubleshooting 32 16 Glossary 33 17 Keyword index 34 ...

Page 5: ...yet configured or the existing configu ration is to be changed Service personnel Technical training for building or electrical installations Special knowledge of the device system is required Checks the product at regular intervals to ensure that it is in good working order services the device or system and repairs it or ex pands and upgrades the system Product already in use and requiring servici...

Page 6: ...le from Siemens AG I BT DE FS SP 76187 Karlsruhe Germany EU directives 1999 5 EC R TTE Radio and telecommunications terminal equipment Compliance with the European Directive 1999 5 EC has been proven by testing according to the following standards Electromagnetic compatibility EN 301 489 1 EN 301 489 17 EMC immunity of alarm systems EN 50130 4 Safety EN 60950 1 Radio requirements EN 300 330 2 EN 3...

Page 7: ...de offline 250 cards 100 priority and 150 peronal cards In Stand alone mode 250 cards Card read distance 1 to 3 cm approx Frequency band 2 4 GHz Indicators 3 x LED red yellow green 1 x buzzer Operating temperature 0 to 50 C Environment Indoor use only IP rating IP30 Colour Stainless steel Dimensions W x H x D 285 x 64 x 59 mm Weight 0 76 kg Approval CE NOTE Lithium batteries must be used because t...

Page 8: ...n Weight RF30 EM GBI 31 118 Codoor 0 76 kg 6 Package contents Check that you have the following parts before discarding the packing materials 1 x RF30 EM batteries excluded 4 extension sleeves for handle nipples use only one pair M4 or M5 1 x reinforcing spring 1 x reinforcing spring holder ...

Page 9: ...tem mode See section 9 System mode 3 Check for communication between the RF30 and the SiPass Bewator Entro system See section 9 2 Service mode 4 Mount the RF30 EM See section 10 Mounting Back to Stand alone mode Erase the system settings and return to the factory default condition See section 12 Erase memory 7 3 Mounting The RF30 EM may be fitted on most doors with handle operated ASSA modular typ...

Page 10: ...m the batteries When the RF30 EM is not in use the power consumption is reduced to a minimum to save batteries PIR sensor A passive infra red PIR sensor wakes up the reader when it detects a person close to the RF30 EM The RF30 EM is thus ready to provide access to the door via card and or Group code PIN See section 10 4 Adjust the PIR sensor 7 6 Keypad 1 2 3 Fig 1 Keypad RF30 EM Red LED Yellow LE...

Page 11: ...n the system reached See installation manual SiPass Bewator Entro Wireless Connecting to the network 7 8 LED status in service mode To enter the Service mode see section 9 2 Service mode LEDs Declaration Service mode Signal strength command A30 Signal strength excellent Signal strength sufficient Signal strength OK Recommendation Relocate the router Signal strength weak Relocate the router Service...

Page 12: ...er to confirm each key press if required The buzzer also sounds to confirm successful programming 7 11 Unlock a door In Stand alone mode either a card or a code can be used to unlock the door The use of a card provides higher security In System mode a card with corresponding code can be used ...

Page 13: ... don t press a key the device will automatically leave the administrator mode after 30 seconds RF30 EM is delivered with the default Administrator code set as 112233 1 Press B 2 Enter the 6 digit Administrator code 3 Press A27 The buzzer sounds a confirm tune 4 Enter a new 6 digit Administrator code The buzzer sounds a confirm tune 5 Verify by entering the same Administrator code again RF30 EM exi...

Page 14: ...de after 30 seconds 1 Remove the RF30 EM from the door 2 Quickly press the reset button on the back of the RF30 EM Fig 2 Reset button on the back The buzzer sounds a confirm tune 3 Enter the desired 6 digit Administrator code The buzzer sounds a confirm tune 4 Verify by entering the same Administrator code again The buzzer sounds a confirm tune If the second input doesn t match the first input the...

Page 15: ...dministrator code 2 Check in the SiPass Bewator Entro software which Segment ID Address and installation key is used in the SR35i 3 Press B 4 Enter the 6 digit Administrator code 5 Enter A80 6 Enter the 4 digit Segment ID 7 Enter the 2 digit Address 01 32 8 Enter the 8 digit Installation key 9 Press A The RF30 EM will operate in System mode If any other key than A is pressed the RF30 EM returns to...

Page 16: ...ngth sufficient Signal strength OK Recommendation Relocate the router Signal strength bad Relocate the router 9 2 2 Check link reliability A31 The command A31 displays the reliability of the data transmission It will proceed for 5 minutes or until a key press or card use Buzzer Description Continuous tones Link reliability OK Sending and receiving messages Non continuous tones One or more messages...

Page 17: ...andle operated mortise locks The distance between the centre of the handle and the centre of the cylinder should be between 105 116 mm Latchbolt function The handle must have an 8 mm square spindle The handle s fixing holes should be at 30 38 mm centres diagonal The RF30 EM can be used with a variety of locks such as ASSA 8561 or 565 The backset should be 70 mm Backset 70 mm Fig 3 RF30 EM door mou...

Page 18: ...ugh into the handle on the inside If this cannot be done cut the spindle to the right length See figure 2 5 Prepare the handle by extending the screws with the supplied extension sleeves M4 or M5 See figure 3 6 Place the RF30 on the outside of the door with the handle attached and pass the lever handle spindle through the square hole See figure 4 7 Ensure that the red mark on the follower point do...

Page 19: ...ormal operation the host system controls the validity of the cards If the RF30 EM loses contact with the system it will operate offline in offline mode The yellow LED will flash slowly if the RF30 EM has never had a connection to the system In this mode the RF30 EM accepts up to 250 cards stored in internal memory These are known as Priority Cards and are identical to the priority cards in SiPass ...

Page 20: ... while the screw is adjusted Fig 4 RF30 EM PIR sensor and screw to adjust the PIR sensor Minimize the PIR sensor radius The door is located in a busy environment for example stores or corridors 1 Turn the screw anticlockwise The sensor moves down Extend the PIR sensor radius The door will be opened from the side instead of the front 1 Turn the screw to the right The sensor moves up ...

Page 21: ...t the command and exit to Administrator mode by pressing A again 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 Press A01 The buzzer sounds a confirm tune or If the memory is full the buzzer will sound an error tune and return to Administrator mode 4 Present the card at the RF30 EM The buzzer sounds a confirm tune 5 Add the next card if required ...

Page 22: ... Administrator mode by pressing A again 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 Press A03 The buzzer sounds a confirm tune If the memory is full the buzzer will sound an error tune and return to Administrator mode 4 Enter the last 8 digits of the card number on the keypad The buzzer sounds a confirm tune 5 Add the next card if required ...

Page 23: ...zer sounds a confirm tune or If the memory is full the buzzer will sound an error tune and return to Administrator mode 4 Enter the the card number of the first card last 8 digits in the series The buzzer sounds a confirm tune 5 Enter the card number of the last card last 8 digits in the series The buzzer sounds a confirm tune LED 1 flashes red continuously as the cards are logged on or If the mem...

Page 24: ...esent the card at the RF30 EM The buzzer sounds a confirm tune 5 Cancel the next card by presenting them at the RF30 EM 11 2 2 Cancel a card by entering its number NOTE If you have entered the wrong Axx command e g in step 3 below you can abort the command and exit to Administrator mode by pressing A again 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 P...

Page 25: ... exit to Administrator mode by pressing A again In parallel with card reading four 4 digit Group codes can be set Each Group code needs to be assigned a group number 1 4 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 Press A21 The buzzer sounds a confirm tune 4 Enter the desired 1 digit group number 1 4 The buzzer sounds a confirm tune 5 Enter the desire...

Page 26: ...he desired 4 digit Group code The buzzer sounds a confirm tune The existing Group code will be over written 6 To change another Group code follow steps 4 5 11 3 3 Delete Group code 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 Press A21 The buzzer sounds a confirm tune 4 Enter the desired 1 digit group number 1 4 The buzzer sounds a confirm tune 5 Enter...

Page 27: ...ounds a confirm tune The door is now locked RF30 EM returns to normal operation 11 5 Disable enable buzzer The default setting is for the buzzer to sound as each key is pressed Change if silent operation is required 1 Press B 2 Enter the 6 digit Administrator code See section 8 Change Administrator code 3 Press A65 The buzzer sounds a confirm tune 4 To enable press 1 or To disable press 0 The buzz...

Page 28: ... The buzzer sounds a confirm tune Fig 5 Reset button on the back 3 Press 112186 The buzzer sounds a confirm tune The buzzer sounds a warning tone to alert that you are about to erase the memory 4 Press 112186 The buzzer sounds a confirm tune The memory is erased After approximately eight seconds the RF30 EM re starts The RF30 EM is in Stand alone mode with the following default settings Administra...

Page 29: ... provides security against unauthorised access since the RF30 EM can never accidentally be left in the unlocked position 13 3 Access blocking To thwart attempts to obtain an access code by trial and error RF30 EM incorporates a blocking function to disable the unit after 12 false key presses three successive incorrect 4 digit codes The unit remains blocked until 2 correct codes are entered success...

Page 30: ...ess A31 Reboot unit Press A32 Reconnect network Press A34 Leave Service mode Press B Normal mode Check status Press 0 for two seconds LEDs dis plays status Green LED OK Otherwise se section 7 7 LED status when connecting Stand alone mode Adding a card by reading it Press B Enter the 6 digit Admin istrator code Press A01 Present the card at the RF30 EM Adding a card by entering its number Press B E...

Page 31: ...ent a valid card at the RF30 EM Disable buzzer Press B Enter the 6 digit Admin istrator code Press A65 To enable press 0 Enable buzzer Press B Enter the 6 digit Admin istrator code Press A65 To disable press 1 Erase memory Erase memory Remove the RF30 EM from the door Press the reset button on the back of the RF30 EM Press 112186 Press 112186 ...

Page 32: ...ound following key presses Activate the buzzer See section 11 5 Disable enable buzzer Check the batteries and change any discharged batteries See section 10 3 Change batteries Batteries are rapidly discharged Frequent use requires frequent change of batteries See section 10 3 Change batteries Check whether the handles returning to the horizontal position Adjust the PIR sensor See section 10 4 Adju...

Page 33: ... string of characters which is used to control access to an application or product Group code a combination of numeric character that an access group pos sesses for verification of identity Installation key binary string of characters which is used as the basis of encryption for the installer PIN Personal identification number a combination of numeric character that a person possesses for verifica...

Page 34: ...nk reliability 16 M Memory 28 Mounting 9 17 Distance between units 19 Fitting RF30 EM 18 Offline mode 19 Test mechanical funktion 19 N Node Address See Address O Offline mode 19 Operation 29 P Package contents 8 PIR sensor 10 adjust 20 Power down and activation 10 S Safety 5 Segment ID 15 Service description 5 service mode 11 Service Mode 16 Signal strength 16 Stand alone mode 9 21 Add a card 21 C...

Page 35: ...Keyword index 35 Siemens AG 04 2010 ...

Page 36: ...Siemensallee 84 D 76187 Karlsruhe www buildingtechnologies siemens com 2010 Copyright by Siemens AG Data and design subject to change without notice Supply subject to availability Document no A6V10201547 Edition 30 04 2010 ...

Page 37: ...Siemens AG RF30 EM Codoor Konfigurationshandbok ...

Page 38: ...e subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Om detta dokument Denna konfigurationshandbok innehåller instruktioner om hur du installerar ställer in konfigurerar och använder RF30 EM För mer information om det fullständiga trådlösa passerk...

Page 39: ...ministratörskod känd 49 8 2 Existerande administratörskod okänd 50 9 Systemläge 51 9 1 Aktivera systemläge 51 9 2 Serviceläge 52 9 2 1 Kontrollera signalstyrka A30 52 9 2 2 Kontrollera länkens tillförlitlighet A31 52 9 2 3 Återstarta RF30 EM A32 52 9 2 4 Återansluta nätverket A34 52 10 Montering 53 10 1 Tekniska detaljer 53 10 2 Installera RF30 EM i dörren 54 10 2 1 Avstånd mellan enheter 55 10 2 ...

Page 40: ... 3 Ta bort gruppkod 62 11 4 Låsa låsa upp dörren 63 11 5 Inaktivera aktivera summern 63 12 Rensa minnet 64 13 Användning 65 13 1 Passage ut 65 13 2 Automatisk återställning 65 13 3 Blockera åtkomst 65 13 4 Reservström 65 14 Översiktskommandon 66 15 Lösa problem 68 16 Förklarande ordlista 69 17 Index 70 ...

Page 41: ...n befintliga konfigurationen behöver ändras Underhållspersonal Teknisk utbildning för bygg eller elinstallationer Specialutbildning på enheten systemet krävs Kontrollerar produkten vid regelbundna intervaller för att säkerställa en god funktion utför underhåll på enheten systemet samt reparationer eller utökar och uppgraderar systemet Produkten är i drift och kräver underhåll 2 2 Allmänna säkerhet...

Page 42: ...ensstämmande kan beställas från Siemens AG I BT DE FS SP 76187 Karlsruhe Tyskland EU direktiv 1999 5 EC R TTE Radio och teleterminalutrustning Överensstämmelse med eurodirektiv 1999 5 EC har testats enligt följande standarder Elektromagnetisk kompatibilitet EN 301 489 1 EN 301 489 17 EMC immunitet för larmsystem EN 50130 4 Säkerhet EN 60950 1 Radiokrav EN 300 330 2 EN 300 328 ...

Page 43: ...o I systemläge offline 250 kort 100 prioriterade och 150 personliga kort I fristående läge 250 kort Avstånd kortavläsning Ca 1 3 cm Frekvensband nätverk 2 4 Ghz Indikatorer 3 x lysdioder röd gul grön 1 x summer Drifttemperatur 0 50 C Omgivning Uteslutande inomhus IP märkning IP30 Färg Rostfritt stål Mått H x B x D 245 x 64 x 59 mm Vikt 0 76 kg OBS Litiumbatterier skall användas då de har följande ...

Page 44: ...F30 EM GBI 31 118 Codoor 0 76 kg 6 Förpackningens innehåll Kontrollera att du har fått följande delar innan du kastar förpackningsmaterialet 1 x RF30 EM exklusive batterier 4 förlängningshylsor för handtagets skruvar använd enbart ett par M4 eller M5 1 x förstärkningsfjäder 1 x förstärkningsfjäderhållare ...

Page 45: ...t Se avsnitt 9 Systemläge 3 Kontrollera kommunikationen mellan RF30 och SiPass Bewator Entro systemet Se avsnitt 9 2 Serviceläge 4 Montera RF30 EM Se avsnitt 10 Montering Återgå till fristående läge Ta bort systeminställningarna och återgå till fabriksinställningarna Se avsnitt 12 Rensa minnet 7 3 Montering RF30 EM kan monteras på de flesta dörrar med ASSA modulära fallås När monterad är det yttre...

Page 46: ...vänds reduceras strömförbrukningen till ett minimum för att spara på batterierna PIR sensor En passiv infraröd PIR sensor väcker läsaren när den detekterar en person i närheten av RF30 EM RF30 EM är då klar att ge åtkomst till dörren via ett kort och eller gruppkod PIN Se avsnitt 10 4 Justera PIR sensorn 7 6 Knappsats 1 2 3 Fig 1 Knappsats för RF30 EM Röd lysdiod Gul lysdiod Grön lysdiod 0 9 Använ...

Page 47: ...e installationshandboken SiPass Bewator Entro Trådlös Ansluter till nätverket 7 8 Lysdiodstatus i serviceläge För att gå till serviceläget se avsnitt 9 2 Serviceläge Lysdiod Betydelse Serviceläge Signalstyrka kommando A30 Signalstyrkan är utmärkt Signalstyrkan är tillräcklig Signalstyrkan är måttlig Rekommendation Flytta routern Signalstyrkan är svag Flytta routern Serviceläge Länkens tillförlitli...

Page 48: ...arje knapptryck om så önskas Summern ger också en signal som anger att programmeringen gått bra 7 11 Öppna dörren I det fristående läget kan antingen ett kort eller en kod användas för att öppna dörren Att använda ett kort innebär högre säkerhet I systemläget kan ett kort med korresponderande kod användas ...

Page 49: ... knapp kommer enheten att automatiskt lämna administratörsläget efter 30 sekunder RF30 EM levereras med den standardinställda administratörskoden 112233 1 Tryck på B 2 Ange den 6 siffriga administratörskoden 3 Tryck på A27 Summern avger en signal för att bekräfta 4 Ange en ny 6 siffrig administratörskod Summern avger en signal för att bekräfta 5 Bekräfta genom att ange den nya administratörskoden ...

Page 50: ...0 sekunder 1 Ta av RF30 EM från dörren 2 Tryck snabbt på återställningsknappen på baksidan av RF30 EM Fig 2 Återställningsknappen på baksidan Summern avger en signal för att bekräfta 3 Ange en 6 siffrig administratörskod Summern avger en signal för att bekräfta 4 Verifiera genom att ange administratörskoden igen Summern avger en signal för att bekräfta Om den andra inmatningen inte stämmer med den...

Page 51: ...rskod 2 Kontrollera i SiPass Bewator Entro programvara vilket segment id vilken adress och installationsnyckel som används i SR35i 3 Tryck på B 4 Ange den 6 siffriga administratörskoden 5 Ange A80 6 Ange ett 4 siffrigt segment id 7 Ange en 2 siffrig adress 01 32 8 Ange ett 8 siffrigt installationsnyckel 9 Tryck på A RF30 EM övergår till systemläge Om någon annan knapp än A trycks ned återgår RF30 ...

Page 52: ...lstyrkan är tillräcklig Signalstyrkan är måttlig Rekommendation Flytta routern Signalstyrkan är svag Flytta routern 9 2 2 Kontrollera länkens tillförlitlighet A31 Kommando A31 visar tillförlitligheten av dataöverföringen Pågår under 5 minuter eller till dess att knapp trycks eller ett kort används Lysdiod Summer Beskrivning Ihållande signal Länken är måttlig Sänder och tar emot meddelanden Avbrutn...

Page 53: ...e flesta dörrar med handtagsreglerade fallås Avståndet mellan mitten på handtag och mitten av cylindern ska vara mellan 105 116 mm Regellåsfunktion Vredet måste ha en 8 mm kantspindel Vredens fixturhål ska vara minst 30 38 mm i diameter RF30 EM kan användas med flera olika typer av lås så som ASSA 8561 eller 565 Inpassningen ska vara 70 mm Backset 70 mm Fig 3 RF30 EM dörrmontering ...

Page 54: ... handtaget på insidan Om detta inte fungerar kapa av spindeln till lämplig längd Se figur 2 5 Förbered handtaget genom att förlänga skruvarna med de medlevererade förlängningshylsorna M4 eller M5 Se figur 3 6 Placera RF30 på utsidan av dörren med handtaget på plats och för in handtagsspindeln genom det fyrkantiga hålet Se figur 4 7 Säkerställ att den röda markeringen på införingshylsan alltid peka...

Page 55: ... 3 Offline läge Vid normal användning kontrolleras kortens giltighet av värdsystemet Men om RF30 EM förlorar kontakt med systemet kommer den att fungera offline i offline läget Den gula blinkar långsamt om RF30 EM inte har haft någon anslutning till systemet se avsnitt 7 7 Lysdiodstatus vid anslutning I det här läget godtar RF30 EM max 250 kort vars uppgifter lagrats i det interna minnet Dessa kor...

Page 56: ...i sensorn samtidigt som skruven justeras Fig 4 RF30 EM PIR sensor och skruv för justering av PIR sensorn Minimera PIR sensorns räckvidd Om dörren befinner sig i en omgivning med mycket folk som passerar t ex i en korridor 1 Vrid skruven motsols Sensorn förs ned Öka PIR sensorns räckvidd Dörren öppnas från sidan istället för framifrån 1 Vrid skruven medsols Sensorn förs uppåt ...

Page 57: ...ndot och gå ur administratörsläget genom att trycka på A igen 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra administratörs kod 3 Tryck på A01 Summern avger en signal för att bekräfta eller Om minnet är fullt kommer summern att avge en felsignal och återgå till administratörsläget 4 Använd kortet på RF30 EM Summern avger en signal för att bekräfta 5 Lägg till nästa kort ...

Page 58: ...läget genom att trycka på A igen 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra administratörs kod 3 Tryck på A03 Summern avger en signal för att bekräfta eller Om minnet är fullt kommer summern att avge en felsignal och återgå till administratörsläget 4 Ange de sista åtta siffrorna på knappsatsen Summern avger en signal för att bekräfta 5 Lägg till nästa kort om tillämp...

Page 59: ...gnal för att bekräfta eller Om minnet är fullt kommer summern att avge en felsignal och återgå till administratörsläget 4 Ange kortnumret för det första kortet sista 8 siffrorna i serien Summern avger en signal för att bekräfta 5 Ange kortnumret för det sista kortet sista 8 siffrorna i serien Summern avger en signal för att bekräfta Lysdiod 1 blinkar röd under hela tiden som korten loggas på eller...

Page 60: ...nvänd kortet på RF30 EM Summern avger en signal för att bekräfta 5 Annullera nästa kort genom att använda kortet vid RF30 EM 11 2 2 Annullera ett kort genom att ange koden OBS Om du har angett ett felaktigt Axx kommando t ex i steg 3 nedan kan du avbryta kommandot och gå ur administratörsläget genom att trycka på A igen 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra admi...

Page 61: ...ratörsläget genom att trycka på A igen Parallellt med kortläsning kan fyra 4 siffriga gruppkoder ställas in Varje gruppkod måste tilldelas ett gruppnummer 1 4 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra administratörs kod 3 Tryck på A21 Summern avger en signal för att bekräfta 4 Mata in ett 1 siffrigt gruppnummer 1 4 Summern avger en signal för att bekräfta 5 Ange öns...

Page 62: ...nge önskad 4 siffrig gruppkod Summern avger en signal för att bekräfta Den befintliga gruppkoden skrivs över 6 För att ändra ytterligare gruppkoder upprepa steg 4 5 11 3 3 Ta bort gruppkod 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra administratörs kod 3 Tryck på A21 Summern avger en signal 4 Mata in med ett 1 siffrigt gruppnummer 1 4 Summern avger en signal 5 Ange 000...

Page 63: ...bekräfta Dörren är nu låst RF30 EM återgår till normal funktion 11 5 Inaktivera aktivera summern Standardinställningen för summern är att avge en signal för varje knapptryck Ändra denna inställning om tyst användning önskas 1 Tryck på B 2 Ange den 6 siffriga administratörskoden Se avsnitt 8 Ändra administratörs kod 3 Tryck på A65 Summern avger en signal för att bekräfta 4 För att aktivera tryck på...

Page 64: ...r Summern avger en signal för att bekräfta Fig 5 Återställningsknappen på baksidan 3 Mata in 112186 Summern avger en signal för att bekräfta Efter det sista knapptrycket avges två korta och en lång signal 4 Mata in 112186 Summern avger en signal för att bekräfta Minnet är nu rensat Efter ungefär åtta sekunder startar RF30 EM om RF30 EM är i fristående läge och har följande standardinställningar Ad...

Page 65: ...att obehöriga kan öppna dörren eftersom RF30 EM aldrig lämnas i olåst läge 13 3 Blockera åtkomst För att förhindra att man försöker öppna dörren genom att prova olika koder i en följd har RF30 EM försetts med en blockeringsfunktion som inaktiverar enheten efter 12 felaktiga koder tre felaktiga 4 siffriga koder i följd Enheten förblir blockerad tills 2 korrekta koder anges i följd 13 4 Reservström ...

Page 66: ...0 Kontrollera länkens tillförlitlighet Tryck på A31 Starta om enheten Tryck på A32 Återanslut nätverk Tryck på A34 Lämna serviceläget Tryck på B Driftläge Kontrollera status Tryck 0 i två sekunder Lysdioderna visar status Grön lysdiod OK I övrigt se avsnitt 7 7 Lysdiodstatus vid anslutning Fristående läge Lägga till ett kort genom avläsning Tryck på B Ange den 6 siffriga admi nistratörsko den Tryc...

Page 67: ...p dörren Tryck på A1A Använd ett giltigt kort på RF30 EM Låsa dörren Tryck på A0A Använd ett giltigt kort på RF30 EM Inaktivera summern Tryck på B Ange den 6 siffriga administratörs koden Tryck på A65 För att aktive ra tryck på 0 Tryck på B för att lämna administratörl äget Aktivera summern Tryck på B Ange den 6 siffriga administratörs koden Tryck på A65 För att inakti vera tryck på 1 Tryck på B f...

Page 68: ... ingen signal vid knapptryck Aktivera summern Se avsnitt 7 9 Lysdiodstatus vid batterivarning Summer Kontrollera batterierna och byt ut tomma batterier Se avsnitt 10 3 Byta batterier Batterierna är snart tomma Intensiv användning kräver frekvent byte av batterier Se avsnitt 10 3 Byta batterier Kontrollera att handtagen går tillbaka i horisontalt läge Justera PIR sensorn Se avsnitt 10 4 Justera PIR...

Page 69: ... Binär teckensträng som används som krypteringsbas för installatören Kort En id bricka i kreditkortsformat Kortägare Person som har rätt till att använda kortet Krypteringsnyckel Binär teckensträng som används för att kontrollera åtkomsten till ett program eller en produkt PIN Personal identification number En kombination av numeriska tecken som en person har för att verifiera sig PIR sensor Passi...

Page 70: ...Lysdiodstatus 47 Länkens tillförlitlighet 52 Lösa problem 68 M Minne 64 Montering 45 53 Avstånd mellan enheter 55 Installera RF30 EM 54 Offline läge 55 Testa den mekaniska funktionen 55 Målgrupp 41 N Nodadress Se Adress O Offline läge 55 P PIR sensor 46 justera 56 Produktbeskrivning 41 R Rensa minnet 64 Reservström 65 S Segment id 51 Serviceläge 47 52 Signalstyrka 52 Standarder och riktlinjer 42 S...

Page 71: ...71 Siemens AG 04 2010 ...

Page 72: ...ensallee 84 D 76184 Karlsruhe www buildingtechnologies siemens com 2010 Copyright Siemens AG Data och konstruktion kan komma att ändras utan föregående meddelande Leverans i mån av tillgång Dokument nr 81807 2 Utgåva 30 04 2010 ...

Reviews: