Chapter 6
Certification
RUGGEDCOM i802
Installation Guide
22
EMC and Environmental Type Tests
Agency
Standards
Comments
Status
CSA C22.2 No. 142, CSA
C22.2 No. 213, UL No. 916,
ANSI/ISA-12.12.01-2007
Hazardous Location
Approved
CSA
CSA C22.2 No. 60950-1-03,
UL 60950-1, UL 508
Safety
Approved
Section 6.3
EMC and Environmental Type Tests
The RUGGEDCOM i802 has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
Test
Description
Test Levels
Enclosure Contact
± 4 kV
IEC 61000-4-2
ESD
Enclosure Air
± 8 kV
IEC 61000-4-3
Radiated RFI
Enclosure ports
20 V/m
Signal ports
± 4 kV @ 5 kHz
IEC 61000-4-4
Burst (Fast Transient)
DC Power ports
± 2 kV @ 5 kHz
Signal ports
± 1 kV line-to-earth
IEC 61000-4-5
Surge
DC Power ports
± 0.5 kV line-to-earth/line
Signal ports
DC Power ports
IEC 61000-4-6
Induced (Conducted) RFI
Earth ground ports
10 V
IEC 61000-4-8
Magnetic Field
Enclosure ports
30 A/m
IEC 61000-4-29
Voltage Dips
DC Power ports
30% reduction for 0.5 period
Signal ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
IEC 61000-4-12
Damped Oscillatory
DC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
Signal ports
10 V Continuous, 100 V for 1 s
IEC 61000-4-16
Mains Frequency Voltage
DC Power ports
10 V Continuous, 100 V for 1 s
IEC 61000-4-17
Ripple on DC Power Supply
DC Power ports
10%
IEEE 1613 EMC Immunity Type Tests
Description
Test Levels
ESD
Enclosure Contact
± 4 kV
Summary of Contents for RUGGEDCOM i802
Page 4: ...RUGGEDCOM i802 Installation Guide iv ...
Page 12: ...RUGGEDCOM i802 Installation Guide Chapter 1 Introduction Description 4 ...
Page 22: ...RUGGEDCOM i802 Installation Guide Chapter 3 Communication Ports Fiber Optic Ethernet Ports 14 ...
Page 28: ...RUGGEDCOM i802 Installation Guide Chapter 5 Dimension Drawings 20 ...
Page 32: ...RUGGEDCOM i802 Installation Guide Chapter 6 Certification EMC and Environmental Type Tests 24 ...