RUGGEDCOM M969
Installation Guide
Chapter 4
Technical Specifications
Gigabit Ethernet Optical Specifications
23
Section 4.4.2
Gigabit Ethernet Optical Specifications
NOTE
• All cabling is duplex type unless otherwise specified.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
Mode
Connector
Cable
Type (µm)
Tx λ (nm)
d
Tx Pwr
(dBm)
(Min/Max)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget (dB)
50/125
MM
LC
62.5/125
850
-9.5/-4
-20
0
0.5
14
8/125
SM
LC
9/125
1310
-9.5/-3
-22
-3
10
17
8/125
SM
LC
9/125
1310
-7/3
-26
-3
25
19
d
Typical.
Section 4.5
Operating Environment
Parameter
Range
Comments
Ambient Operating Temperature
-40 to 85° C (-40 to 185° F)
e
Ambient Temperature as measured from a 30 cm (12 in.) radius
surrounding the center of the RUGGEDCOM M969 enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage Temperature
-40 to 85° C (-40 to 185° F)
IP Rating
IP67
Operating Altitude
0 to 15240 m (0 to 50000 ft)
Over temperature range of -40 to 85° C (-40 to 185° F)
e
Reduced to -40 to 80 °C (-40 to 76 °F) when equipped with a 100Base-FX, single-mode, 1300 nm, long-reach 90 km port(s).
Section 4.6
Mechanical Specifications
Dimensions
Refer to
Weight
2.86 kg (6.3 lb)
Ingress Protection
IP65, IP67
Summary of Contents for RUGGEDCOM M969
Page 4: ...RUGGEDCOM M969 Installation Guide iv ...
Page 14: ...Chapter 1 Introduction RUGGEDCOM M969 Installation Guide 6 Description ...
Page 24: ...Chapter 2 Installing the Device RUGGEDCOM M969 Installation Guide 16 Ingress Protection ...
Page 44: ...Chapter 6 Accessories RUGGEDCOM M969 Installation Guide 36 LC Fiber Optic 2 unit ...