Technical specifications
RUGGEDCOM RM1224
42
Operating Instructions, 10/2016, RC1260-EN-02
Transmission speed
Downlink: up to 85.6 kbps.
Uplink: up to 85.6 kbps.
GSM (CSD dial-in)
Properties
Radio Link Protocol (RLP) V.110, non-
transparent
Transmission speed up to 14.4 kbps
SMS (TX)
Properties
Text mode, SMSoverIP
Electrical data
Power supply
Quantity
1
Design
Terminal block, 5 terminals
Properties
Input voltage:
12 to 24 VDC
min. 10.8 VDC, max. 28.8 VDC
Maximum power consumption 8 W
Maximum cable length < 3 m
Digital input
Quantity
1
Design
Terminal block, 2 terminals
Properties
Rated voltage 24 VDC Safety Extra Low Voltage
(SELV)
For state "1": 10 to 30 VDC
For state "0": -30 to 3 VDC
Maximum input current 8 mA
Maximum cable length < 3 m
Inputs isolated from electronics.
Digital output
Quantity
1
Design
Terminal block, 2 terminals
Properties
Rated voltage 24 VDC Safety Extra Low Voltage
(SELV)
Relay, internally not current limited
Maximum current carrying capacity 1 A
Maximum cable length < 3 m
Output isolated from electronics
Permitted ambient conditions
Ambient temperature
During operation
-20 ℃ to +75 ℃
During storage
-40 ℃ to +85 ℃
During transporta-
tion
-40 ℃ to +85 ℃
Relative humidity
During operation
≤ 95% at 25 °C, no condensation
Design, dimensions and weight
Module format
Compact module S7-1500
1
UL certified operational temperature range -20 °C to +70 °C
2
IEC environmentally type tested (16 hours) from -40 °C to +75 °C
Summary of Contents for RUGGEDCOM RM1224
Page 16: ......
Page 24: ......
Page 38: ......
Page 44: ......