Technical Specifications
5.5 Fiber Optic Ethernet Port Specifications
Typical distance. Dependent on the number of connectors and splices.
RMS 1 minute.
5.5
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered
with the RUGGEDCOM RS910.
Note
• All optical power numbers are listed as dBm averages. To convert from average
to peak, add 3 dBm. To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens sales associate when
determining maximum segment distances.
10Base-FL Fiber Optic
Tx (dBm)
Mode Connec-
tor Type
Tx λ
(nm)
Cable
Type
(µm)
Mini-
mum
Maxi-
mum
Rx Sen-
sitivity
(dBm)
Rx Satu-
ration
(dBm)
Dis-
tance
(km)
Power
Budget
(dB)
62.5/125
850
-16
-9
18
MM
ST
50/125
850
-19.8
-12.8
-34
-11.2
2
14.2
Typical.
100Base-FX Fiber Optic
Tx (dBm)
Mode Connec-
tor Type
Tx λ
Cable
Type
(μm)
Mini-
mum
Maxi-
mum
Rx Sen-
sitivity
(dBm)
Rx Satu-
ration
(dBm)
Dis-
tance
Power
Budget
(dB)
50/125
-22.5
-14
-33.5
-14
2
11
MM
MTRJ
1300
62.5/125
-19
-14
-33.5
-14
2
14.5
50/125
-22.5
-14
-33.9
-14
2
11.4
MM
SC
1300
62.5/125
-19
-14
-33.9
-14
2
14.9
50/125
-22.5
-14
-33.9
-14
2
11.4
MM
ST
1300
62.5/125
-19
-14
-33.9
-14
2
14.9
MM
LC
1310 62.5/125
-19
-14
-32
-14
2
13
SM
ST
1310
9/125
-15
-7
-34
-3
20
19
SM
LC
1300
9/125
-15
-8
-38
-3
20
23
SM
LC
1310
9/125
-5
0
-35
-3
50
30
SM
LC
1310
9/125
0
5
-37
0
90
37
SM
SC
1300
9/125
-15
-8
-31
-7
20
16
SM
SC
1310
9/125
-5
0
-34
-3
50
29
SM
SC
1310
9/125
5
0
-37
0
90
42
RUGGEDCOM RS910
Installation Manual, 02/2020, C79000-G8976-1029-09
29