Certification
6.2 EMC and Environmental Type Tests
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RS910L meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports. Class 1 allows for temporary communica-
tion loss, while Class 2 requires error-free and interrupted communications.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz
DC Power Ports
± 4 kV
AC Power Ports
± 4 kV
Fast Transient
Earth Ground Ports
± 4 kV
Signal Ports
2.5 kV Common Mode @ 1 MHz
DC Power Ports
2.5 kV Common and Dif-
ferential Mode @ 1 MHz
Oscillatory
AC Power Ports
2.5 kV Common and Dif-
ferential Mode @ 1 MHz
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kV (Failsafe Relay)
DC Power Ports
2 kV
Dielectric Strength
AC Power Ports
2 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40
°F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185
°F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (Non-Con-
densing), 55 °C
(131 °F), 6 Cycles
IEC 60255-21-1
Vibration
2 g @ 10 to 150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
RUGGEDCOM RS910L
Installation Manual, 02/2020, C79000-G8976-1030-06
39