RUGGEDCOM RS930W
Installation Guide
Chapter 6
Certification
EMI and Environmental Type Tests
29
Test
Description
Test Levels
Severity Levels
DC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
AC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
3
Signal ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power ports
10%
3
Signal ports
2 kVAC (Fail-Safe Relay output)
DC Power ports
1.5 kVDC
Dielectric Strength
AC Power ports
2 kVDC
Signal ports
5 kV (Fail-Safe Relay Output)
DC Power ports
5 kV
IEC 60255-5
HV Impulse
AC Power ports
5 kV
IEEE 1613 (C37.90.x) EMI Immunity Type Tests
NOTE
The RS930W meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for
copper ports.
IEEE Test
IEEE 1613
Clause
Description
Test Levels
Enclosure Contact
+/- 8 kV
C37.90.3
9
ESD
Enclosure Air
+/- 15 kV
C37.90.2
8
Radiated RFI
Enclosure ports
35 V/m
Signal ports
+/- 4 kV @ 2.5 kHz
DC Power ports
+/- 4 kV
AC Power ports
+/- 4 kV
Fast Transient
Earth ground ports
+/- 4 kV
Signal ports
2.5 kV common mode @ 1MHz
DC Power ports
2.5 kV common and
differential mode @ 1MHz
C37.90.1
7
Oscillatory
AC Power ports
2.5 kV common and
differential mode @ 1MHz
Signal ports
5 kV (Failsafe Relay)
DC Power ports
5 kV
HV Impulse
AC Power ports
5 kV
Signal ports
2 kVAC (Failsafe Relay)
C37.90
6
Dielectric
Strength
DC Power ports
1.5 kVDC