RUGGEDCOM WIN
User Guide
Chapter 5
Setup and Configuration
Configuring the Scanner
53
• the transmission preamble
• the CINR R1 value
• the RSSI value, in dBm
To configure the scanner, do the following:
1. Navigate to
WiMAX
. The
Scanner Settings
screen appears.
1
2
Figure 46: Scanner Settings Screen
1.
Add
2.
Delete
2. Click
Disconnect
.
3. In the
Autoconnect CINR threshold
parameter, type a value to define the threshold.
4. Click
Add
. A new row appears in the table. You can add up to 32 rows to the table.
5. Configure the following parameter(s) as required:
Parameter
Description
Priority
Synopsis:
A numeric value.
Sets the priority for the scanning table entry. Priority is ranked in
numeric order.
Bandwidth [MHz]
Synopsis:
{3.5MHz, 5MHz, 7MHz, 10MHz}
Displays the bandwidth of the scanning table entry.
Start frequency [kHz]
Displays the start of the scanning range as a frequency in
kilohertz.