RUGGEDCOM WIN5151
Installation Guide
Chapter 4
Technical Specifications
Mechanical Specifications
31
b
Non-condensing
Section 4.5
Mechanical Specifications
Weight
1.5 kg (3.3 lb)
Ingress Protection
IP67
Enclosure
Aluminum
Section 4.6
IDU to ODU Cable Specifications
IDU to ODU Cable
Applications
Outdoor installations, fixed or portable installations, digital distribution frames in transmission stations,
outdoor installations in harsh environments.
General Construction
Custom made cable designed specially for wireless systems, meeting the requirements of Cat. 5e per
ANSI/TIA/EIA-568-B.2 and IEC 61156-5. The cable contains 4 twisted pairs, cabled, foil-tape shielded and
jacketed with two special black UV resistant, flame retardant PVC compounds for direct outdoor use in
harsh electrical environments. The diameter of the inner core complies with RJ45 connecting hardware
allowing direct connection to equipment without patch cords.
Conductor Size
0.52 mm
Outer Jacket Material
UV resistant FR-PVC
Outer Diameter
7.9 mm (0.31 in) nominal
Weight
68.0 kg/km
IDU to ODU Cable Design and Materials
Conductor Material
Bare Copper
Conductor Size
24 AWG
Insulation Material
Solid PO
Insulation O.D.
1.07 mm (0.04 in)
Color Code
Per TIA/EIA 568-B
Overall Foil Shield
Yes
Overall Shield Material
Aluminum/Polyester Foil
Overall Foil Design
100% Coverage
Overall Drain-wire Material
Tinned Copper
Overall Drain-wire Size
24 AWG