Chapter 1
Introduction
RUGGEDCOM WIN5214
Installation Guide
4
Required Tools and Materials
Chassis Ground Connection
Protects the subscriber unit from power surges and accumulated static electricity. For
information about grounding the subscriber unit, refer to
Section 1.3
Required Tools and Materials
The following tools and materials are required to install the RUGGEDCOM WIN5214:
Kits
• Class I, Division 2 Kit (P/N MKIT0090) – For hazardous
locations only
Tools
• Wrench or socket set
• Phillips screwdriver
• Drill with an 8 mm (5/16 in) drill bit
• Wall anchors (if necessary)
Sprays
• Cleaner and de-greaser
• SCC3 conformal coating
• Corrosion protection
Greases
• Marine grease (for marine applications only)
Tapes
• POE cold shrink (maximum 49.2 mm or 1.9 in inner
diameter before shrinking) or self-amalgamating tape
• UV-resistant vinyl tape
• Electrical insulation putty
Mounting Hardware (Wall/Tower Only)
• Four 1/4" × 1/2" HEX chipboard screws
• Four 1/4" flat washers
• Four 1/4" spring washers
Section 1.4
Decommissioning and Disposal
Proper decomissioning and disposal of this device is important to prevent malicious users from obtaining
proprietary information and to protect the environment.
Decommissioning
This device may include sensitive, proprietary data. Before taking the device out of service, either permanently or
for maintenance by a third-party, make sure it has been fully decommissioned.
For more information, refer to the associated
User Guide
.
Recycling and Disposal
For environmentally friendly recycling and disposal of this device and related accessories, contact a facility
certified to dispose of waste electrical and electronic equipment. Recycling and disposal must be done in
accordance with local regulations.