Maintenance
1.26
Standard times
Straightforward resetting of all time switch programs to their standard values.
The standard time program resets the time settings of all time switch programs. For this
purpose, the controller is supplied with non-volatile factory settings.
Setting
The standard time program is activated as soon as the display changes to 1.
Display
Unit
0 / 1
-
In that case, the individual settings will be lost!
The time settings will be overwritten with the standard values. This applies to the
following settings:
•
Only the switching times of time switch program 1 or 2
preselected with the heating circuit selection button will be
overwritten.
...
•
The switching times of time switch program 3 (d.h.w.) will be
overwritten.
...
Switching point
Setting line
Standard time
Period 1 ON
6
-
20
06 : 00
Period 1 OFF
7
-
21
22 : 00
Period 2 ON
8
-
22
– – : – –
Period 2 OFF
9
-
23
– – : – –
Period 3 ON
10
-
24
– – : – –
Period 3 OFF
11
-
25
– – : – –
Time switch program
1 or 2
-
3
Benefit
Description
Caution
Effect
standard values