Ordering Information
9 7
External Accessories
Key Interlocks
Accessory
Catalog Number
Installed on Breaker
Provision only
Circuit Breaker
Drawout
KISB, SISB
KIPOF
SKIPOD, 20KIPOD
Remote Indication Panel
Accessory
Catalog Number
Remote Indication Relay Panel
SBRIP
Display Module
Accessory
Catalog Number
Display Module
SBDM
Ground Fault Display Module
Accessory
Catalog Number
Ground Fault Display Module
SBGFM
Auxiliary Power Source For Electronic Trip
Unit
Accessory
Catalog Number
Auxiliary Power Source
SBAPM
Universal Trip Unit Test Kit
Accessory
Catalog Number
Test Kit
TS31
UL Listings and File Numbers
UL Listing
File Number
Trip Unit
Breaker
Draw Assembly
Accessories
CSA Guides
E9896
E9896
E135453
E57501
LR57039
Time Current Curves
Description
Catalog Number
Time Current Curves
TD7210
Electric Operator Troubleshooting Guide
Symptom
Solutions
Motor does not run.
1. Check for springs already charged by checking spring charge indicator.
2. Check for rated voltage at LT1 and LT5.
3. Check motor fuse - requires 1.8A Slo-Blo fuse.
4. Check all wiring connections.
5. If the lamp connected to LT4 is blinking slowly (one second on, two seconds off) remove power from LT1 and LT5 then
re-apply power
Motor runs for 20 seconds, does not charge
springs, lamp on LT4 blinks slowly (one
second on, two seconds off).
1. Remove power from LT1 and LT5, manually charge breaker. Reapply power to LT1 and LT5 motor should run for less than
10 seconds and shut off. Lamp on LT4 should remain on.
Breaker will not close electrically.
1. Check to see if springs are charged by checking charged indicator flag.
2. Check for power on LT1 and LT5.
3. Check for power on LT2. If power is on LT2, remove and reapply.
4. Check to see if breaker is locked in open position by either padlocking device, kirk key, or drawout interlock.
5. Check all wiring connections.
Lamp on LT4 blinks slowly (one second on,
two seconds off).
1. Remove power from LT1 and LT5, manually charge breaker springs. Reapply power to LT1 and LT5. Lamp on LT4 should
remain on.
Mechanical Interlock
Accessory
Catalog Number
800A, 1200A Envelope
Fixed Circuit Breaker
Drawout Circuit Breaker
SBMIF08
SBMID08
2000A Envelope
Fixed Circuit Breaker
Drawout Circuit Breaker
SBMIF20
SBMID20
Cell Switches
Accessory
Catalog Number
1A & 1B
2A & 2B
3A & 3B
4A & 4B
CEL1
CEL2
CEL3
CEL4
Capacitor Trip
Accessory
Catalog Number
Capacitor Trip
Consult Siemens
Breaker Closing Blocking Device
Accessory
Catalog Number
Breaker Closing Blocking Device
SBBD
Padlock Devices
Accessory
Catalog Number
Installed on Breaker
Installed on Drawout
SBPLB
SBPLD
Summary of Contents for SBA 1200
Page 68: ...66 External Accessories Ground Fault Sensing and Relaying Courtesy of NationalSwitchgear com ...
Page 94: ...92 Outline Dimension Drawing 2000A Fixed Mounted Courtesy of NationalSwitchgear com ...
Page 95: ...93 Outline Dimension Drawing 2000A Fixed Mounted Courtesy of NationalSwitchgear com ...
Page 100: ...98 Courtesy of NationalSwitchgear com ...
Page 101: ...Electrical Diagrams 99 Courtesy of NationalSwitchgear com ...
Page 102: ...100 Electrical Diagrams Courtesy of NationalSwitchgear com ...