background image

SC7 / SC7P / UK – 06.14

 

 

 

 

 

 

Connection to an Entro Lite DC800 Door Controller

 

 

 

 

Configuration

 

Following jumper selections must be done: 

 

Reader type (J4) must be put on the Wiegand 

 

Voltage jumper (J1) to VIN 

 

Function jumper (J3) to Entro Lite 

 

(Note - if the DC800 is used in Entro - set J3 to Entro) 

 

Operation

 

 

When the Reader is powered the LED is flashing for 5 seconds.  After these 5 

seconds the LED flashes by the sequence red, yellow and green before the LED is 

switched off and the Reader is ready for use. 

When a Smart Card is provided within the reading sector of the SC7 and the card is 

accepted, the yellow LED is lit for approximately 0.5 seconds at same time as a message 

is sent out.  The yellow LED is only lit when a message is sent out from the Reader.  After 

this the Reader goes back to wait state, code from the same card is not sent again before 

a time of 3 seconds has been elapsed provided the card has been out of the reading 

sector. 

 

Technical Specifications

 

 

Power Supply: 

24V (+10 / +30 V) 

Current consumption: 

100mA max 

Interfaces: 

Wiegand

 

Clock and Data 

Housing: 

Plastic 

Dimensions: 

SC7: 110 x 43 x 24

 

(H x W x D)mm: 

SC7P:138 x 43 x 24

 

Temperature: 

-

40 to 55°C

 

 

Storage temperature: 

-40 to 55°C

 

IP Rating: 

SC7:IP67

 

SC7P:IP47

 

Connection: 

3m cable 

Led: 

Tricolor 

Buzzer: 

Yes

 

Carrier frequency: 

13.56 MHz

 

 

 

Reviews: