Appendix D
D
D.1
Messages in the event log
Messages during system startup (general)
Alarm
Description
Warm start performed, Ver: V02.00.00 - event/
status summary after startup
Type of startup and the loaded firmware version.
Power supply:
● L1 is connected
● L2 is not connected
Status of the power supplies line 1 and line 2.
No line is monitored
Information about monitoring the power supply from the signaling system.
MSTP disabled
MSTP enabled
Information on the status of the Spanning Tree protocol.
No Fault states pending after startup
Fault state following system start.
Status of the power supply
You enable or disable the "Power Change" event in "System > Events".
Alarm
Description
Power up on line 1 / 2 / PoE.
Power supply exists on line 1, line 2 or PoE..
Power down on line 1 / 2 / PoE.
Power supply interrupted on line 1, line 2 or PoE.
Status of the Ethernet interface
You enable or disable the "Link Change" event in "System > Events".
Alarm
Description
Link up on P1.
A connection exists on the Ethernet interface.
Link down on P1.
No connection exists on the Ethernet interface.
Status of the WLAN interface (in access point mode only)
Messages
Link down up VAP X.Y.
The VAP interface Y on the WLAN interface X is enabled.
Link down on VAP X.Y.
The VAP interface Y on the WLAN interface X is disabled.
WDS Y at WLAN X is up.
A link exists on the WDS interface Y of WLAN interface X.
WDS Y at WLAN X is down.
No link exists on the WDS interface Y of WLAN interface X.