Configuration / project engineering
5.6 Configuration with Web Based Management
SCALANCE W786-xPRO
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
101
If you want to deactivate the option of configuration with Web Based Management, you can
do this in the Security Wizard over Telnet and SNMP. Settings made using the Security
Wizard only take effect after a restart on the device.
See also
CLI
\
SYSTEM
\
SERVICES menu command (Page 177)
5.6.3.4
Restart menu command
Restart
button
Click this button to restart the device. During a restart, the device is reinitialized, the internal
firmware is reloaded, and the device runs a self-test. The learned entries in the address table
are deleted. You can leave the browser window open while the device restarts.
Restore Memory Defaults
button
Click this button to reset the configuration. The following parameters (protected defaults) are
not reset:
●
IP address
●
Subnet mask
●
Gateway address
●
SSID
●
IP address of the default router
●
DHCP flag
●
System name
●
System location
●
System contact
●
Device mode
●
Country code
There is no automatic restart. This allows you to enter data using Web Based Management
before the restart. The changes take effect only after a restart.
If you are logged on as user, the "Restore Memory Defaults" button is not visible.
Restore Factory Defaults and restart
button
Click on this button to restore the factory configuration settings. The protected defaults (see
above) are also reset. The C-PLUG is reinitialized and formatted if it exists. An automatic
restart is triggered.