Connecting up
4.8 Inserting / removing the C-PLUG
SCALANCE W786-xPRO
60
Operating Instructions, Release 08/2007, C79000-G8976-C221-02
4.8
Inserting / removing the C-PLUG
Inserting the C-PLUG
Figure 4-9
Location of the C-PLUG with the housing cover removed
The housing of the C-PLUG has a protruding ridge on the long side. The C-PLUG can only
be inserted when this ridge is at the top right. The slot in the SCALANCE W786 has a
corresponding groove at this position. Make sure that the C-PLUG is inserted completely into
the slot.
Removing the C-PLUG
Insert a screwdriver between the right-hand front edge of the C-PLUG and the slot and
release the C-PLUG.