After you run the
dtime
command, run the
apply
command to implement the change.
dtime 200-5000
Parameters
200-5000
Specifies the dwell time of the scan group in milliseconds.
Example
The following example sets the channel dwell time of scan group South Block to 200 milliseconds:
WLC.siemens.com
:mitigator:scgroup:South Block# dtime 200
WLC.siemens.com
:mitigator:scgroup:South Block# apply
interval
Use the
interval
command to modify the scan time interval in minutes. Valid values are from 10 to
120 minutes.
After you run the
interval
command, run the
apply
command to implement the change.
interval period
Parameters
period
Specifies the scan time interval period in minutes
Example
The following example modifies the scan time interval to 30 minutes:
WLC.siemens.com
:mitigator:scgroup:South Block# interval 30
WLC.siemens.com
:mitigator:scgroup:South Block# apply
radio
Use the
radio
command to modify the radio mode to be used for scanning.
After you run the
radio
command, run the
apply
command to implement the change.
radio radio1|radio2|both
Parameters
radio1
Specifies radio 1 to be used
radio2
Specifies radio 2 to be used
both
Specifies both radio 1 and radio 2
Radar Commands
interval
SCALANCE WLC711 CLI Reference Guide
179