fileName
Specifies the file name for the TCPDump
Examples
The following example specifies the file name as TrafficCapture for the TCPDump:
WLC.siemens.com
:traffic_capture# file_name TrafficCapture
size
Use the
size
command to specify the file size of TCPDump file. The
size
command is accessible from
the traffic_capture context of the CLI.
Refer to the Wireless Appliance Convergence Software Maintenance Guide for more information.
size filesize
Parameters
filesize
Specifies the file size of TCPDump file. File size can range from 10 MB
(minimum) to a maximum of 1 GB.
Example
The following example specifies the file size of the TCPDump file as 15MB:
WLC.siemens.com
:traffic_capture# size 15
interface
Use the
interface
command to specify the interface on which the exception traffic is to be captured.
interface interfacename
Parameters
interfacename
The interface name on which the exception traffic is to be captured. You
can choose any of the following interfaces:
•
Management Port (eth0)
•
Physical esa ports
•
Defined VNS
traffic_capture Commands