Installation
4.3 Installation on a standard rail
SCALANCE X-200
132
Operating Instructions, 12/2011, A5E00349864-19
4.3
Installation on a standard rail
Installing an IE Switch X-200 on a SIMATIC S7-300 standard rail
1.
Place the upper guide at the top of the IE Switch X-200 housing in the S7 standard rail.
2.
Screw the IE Switch X--200 to the underside of the standard rail.
3.
Fit the connectors for the power supply.
4.
Fit the connectors for the signaling contact.
5.
Insert the terminal blocks or M12 cable connectors into the sockets on the IE Switch X-
200.
Figure 4-3
IE Switch X-200 installation on a SIMATIC S7-300 standard rail
Uninstalling
Removing an IE Switch X-200 from a SIMATIC S7-300 standard rail
1.
First disconnect all connected cables.
2.
Loosen the screws on the underside of the S7 standard rail and lift the IE Switch X-200
away from the rail.
Summary of Contents for SCALANCE X-200
Page 12: ...Table of contents SCALANCE X 200 12 Operating Instructions 12 2011 A5E00349864 19 ...
Page 284: ...Technical specifications SCALANCE X 200 284 Operating Instructions 12 2011 A5E00349864 19 ...
Page 288: ...References SCALANCE X 200 288 Operating Instructions 12 2011 A5E00349864 19 ...
Page 294: ...Dimension drawings SCALANCE X 200 294 Operating Instructions 12 2011 A5E00349864 19 ...