Troubleshooting NL
Malfunction
Cause
Troubleshooting
E:32-00 lights up alternately
or the water supply indicator
lights up.
The sieves in the water connection
1.
Switch off the device.
2.
Remove the plug from the socket.
3.
Turn off the tap.
4.
Unscrew the water connection.
5.
Remove the strainer from the inlet hose
inlet or AquaStop
hose are clogged.
6.
Clean the strainer.
7.
Place the strainer in the supply hose.
8.
Screw on the water connection.
9.
Check the water connection for
leaks.
10.
Put the plug back in the
socket.
11.
Switch on the device.
E:92-40 lights up alternately.
Strainers are dirty or clogged.
▶
Clean the sieves.
E:61-03 lights up alternately.
The water is not pumped
out.
Drain hose is clogged or
kinked.
1.
Route the drain hose without
kinks.
2.
Remove the remains.
Siphon connection is still closed.
▶
Check the connection to the
fon and open it if necessary.
Drain pump cover is
loose.
▶
Remove the cover of the "drain
Page 53 well fixed.
E:61-02 lights up alternately.
Drain pump is blocked.
▶
Clean the drain pump.
Drain pump cover is
loose
▶
Remove the cover of the "drain
Page 53 well fixed.
41