Safety instructions
2.1 Basic information
SICHARGE D
Operating Instructions, 02/2021, 8EM5907-0AA00-1AA7.01
11
Protection against ingress of liquid
The IP54 degree of protection of the cabinet protects the charging station from ingress of
water splashing against it from all directions. In particular, the protection standard prevents
the penetration of precipitation and protects against all liquids applied to the surface of the
cabinet without pressure.
Also protect the charging station from liquids that exert pressure on the surface of the
cabinet:
•
Never use high-pressure cleaners or steam cleaners when cleaning the charging station.
•
Place the charging station in a flood-proof location.
WARNING
Electric shock due to ingress of liquid
Strong jets of water or flooding can cause liquid to enter the charging station. Moisture or
liquid inside the charging station can cause electric shock.
If liquid has entered the charging station, take the following safety precautions:
•
Take the charging station out of service by switching it off at the electrical distributor.
•
Qualified personnel must dry the charging station and check it for damage.
Protection against unauthorized opening
A lock system protects the charging station from unauthorized opening of the device doors at
the front and back.
•
Keep the key for the door locks safe against access by unauthorized persons.
•
Only make the key available to authorized persons for work in the charging station.
•
Do not leave the charging station unattended with the device door open.
Note
The charging station is supplied with replaceable locking cylinders and matching keys.
For protection against unauthorized opening, the lock cylinders should be replaced by the
operator and the matching keys should be stored in a safe place. For maintenance work, the
operator should allow maintenance personnel access to the charging station.
Use different lock cylinders for each individual charging station. This ensures that each
charging station can only be opened by the matching key.
Replacing the lock cylinders
The charging station is supplied with replaceable lock cylinders (standard half cylinders
according to DIN 18252) and matching keys. You will find detailed instructions on replacing