SICHARGE UC Dispenser UL |
Operating Instructions
Minimum clearances for wall mounting
For operation and maintenance and to ensure proper ventilation of the SICHARGE UC dispenser, you
must maintain the following minimum clearances (in mm):
Figure 4-4
Minimum clearances for wall mounting (front view)
Maximum allowable temperature at air inlet
The maximum permissible ambient temperature is 45 °C. When the ambient temperature
exceeds 45 °C,
the charging process is interrupted. The SICHARGE UC dispenser must not be operated above the
maximum permissible ambient temperature.
Direction of air flow
Please note the direction of air flow when using the following options:
• Air-conditioning unit:
The supply air enters the SICHARGE UC dispenser from the front.
The exhaust air escapes
on both sides at the top.
Avoid recirculating the exhaust air for cooling.
36