Controllers
4.5 Relay and fieldbus interfaces
ATD4xxW Door Controller for Industrial Applications
122
System Manual, 01/2017, A5E38080677-AB
GSD file
All other slave functionality is described in the corresponding GSD file.
Table 4- 8
GSD file
GSD file
Download
SIEM81BA.GSD
The GSD file is available online at Industry online support
http://support.automation.siemens.com/WW/view/en/99008084
You can find explanations of the basic functions and communication properties of the DP
slave in the section PROFIBUS communication (Page 129).
Task
The PROFIBUS module enables the SIDOOR ATD420W door controller to be connected to
a PROFIBUS fieldbus.
Interface
The ATD420W system is implemented as a slave using the DP-V0 protocol. Data transfer is
cyclic with a class 1 DP master.
An ASIC of the "SPC3" type is used for interfacing to PROFIBUS. RS 485 in accordance
with ANSI TIA/EIA 485-A is used as the transmission technology. Corresponding bus
connections must be provided at the individual bus stations or nodes for fail-safe functioning
of the PROFIBUS.