Controllers
4.5 Relay and fieldbus interfaces
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
131
Table 4- 13 User parameter byte 3
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 User parameter byte 1
x
x
x
x
x Telegram type
The telegram type is set with bits 0 to 2.
Codes:
Standard telegram = 0000
Mirror telegram = 0001
Broadcast = 0010
Special telegram = 0011
Special telegram with broadcast = 0100
Factory setting = standard telegram (0000)
0
0
0
Reserved
Table 4- 14 User parameter bytes 4 and 5
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 User parameter byte 1
0 to 234 (0x00 to 0xEA)
Cycle time (high byte)
0 to 96 (0x00 to 0x60)
Cycle time (low byte)
The cycle time is given in [ms]. The cycle time
defines the minimum time intervals at which the
slave is queried by the master.
Time range = 10 to 60000 ms.
Factory setting = 100 ms (0x0014)
Table 4- 15 User parameter bytes 6, 7 and 8
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 User parameter byte 1
0
0
0
0
0
0
0
0
Reserved