Controllers
4.5 Relay and fieldbus interfaces
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
145
Table 4- 23 Startup parameter record byte 3
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Telegram type parameter
X
X
X
X
X Telegram type
The telegram type on the internal bus is set via bits 0 to 2.
The following coding results:
Default telegram = 0000
b
Mirror telegram = 0001
b
Broadcast = 0010
b
Special telegram = 0011
b
Default = default telegram
0
0
0
Reserved
Table 4- 24 Startup parameter record bytes 4 and 5
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Cycle time parameter
0 to 234 (0x00 to 0xEA)
Cycle time (high byte)
0 to 96 (0x00 to 0x60)
Cycle time (low byte)
The cycle time is given in [ms]. The time range is between
10 and 60000 ms. The cycle time specifies at what mini-
mum intervals communication takes place on the internal
bus.
The default is 100 ms = 0064
hex
Table 4- 25 Startup parameter record bytes 6, 7 and 8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Parameter
0
0
0
0
0
0
0
0 Reserved
Summary of Contents for SIDOOR ATD401W
Page 1: ......