Driving curve
The optimum drive characteristics of the door are calculated and maintained continuously.
The driving curve transitions are rounded off so that the door movement is smooth and jerk-
free.
v* Speed open
v**
Speed close
①
Slow start distance open
Slow end distance close
②
Slow start speed open
Slow end speed close
③
Acceleration ramp open
Acceleration ramp close
④
Maximum speed open
Maximum speed close
⑤
Reversal ramp open/close
Reversal ramp close/open
⑥
Deceleration ramp open
Deceleration ramp close
⑦
Slow end speed open
Slow start speed close
⑧
Slow end distance open
Slow start distance close
Reversal ramp close/open = Reversal of travel in direction "CLOSE" in direction "OPEN".
Reversal ramp open/close = Reversal of travel in direction "OPEN" in direction "CLOSE".
When reversing, the door is braked with the reversal ramp and starts the travel in the
opposite direction with the acceleration ramp.